72-DVT30N-2
7
SPECIFICATIONS
This appliance is tested and safety approved under the following US and Canadian gas appliance standards:
-
ANSI Z21.88
-
2019 / CSA 2.33
-
2019 Vented Gas Fireplace Heaters,
-
CAN/CGA
-
2.17
-
M91 Gas
-
Fired Appliances For Use at High Altitudes,
-
CSA –
P.4.1
-
15 –
Testing Method for Measuring Annual Fireplace Efficiency,
-
CSA C22.2 No.3
-
M1998(R.2014)
-
Electrical Features of Fuel
-
Burning Equipment
Commonwealth of Massachusetts:
This appliance has been manufactured in accordance with Massachusetts
code 248 CMR 5.00.
Approval Code: G1
-
0319
-
387
. (http://license.reg.state.ma.us/public/licque.asp).
Please contact Archgard Industries Ltd., if you have any questions regarding the certification of this appliance.
APPLIANCE CERTIFICATION
INSTALLATION CODES
This appliance must be installed by a qualified gas appliance installer. The installation must conform with the
local codes or, in the absence of local codes, with the current National Fuel Gas Code, ANSI Z223.1/ NFPA 54.
Electrical connections and grounding must conform with local codes, or current National Electrical code, ANSI/
NFPA No. 70
-
1987.
We recommend that our gas hearth products be installed and serviced by professionals who are
certified in the U.S. by the National Fireplace Institute
®
(NFI) as NFI Gas Specialists.
Natural Gas (NG)
Propane (LP)
Manifold Pressure
1.6
-
3.5 in. w.c. (0.4
-
0.9 kPa)
6.4
-
10.0 in. w.c. (1.6
-
2.5 kPa)
Min. Supply Pressure
Max Supply Pressure
5 in. w.c. (1.2 kPa)
14 in. w.c. (3.5 kPa)
11.0 in. w.c. (2.8 kPa)
14.0 in. w.c. (3.5 kPa)
Orifice Size
#37 DMS (2.65 mm dia.)
#52 DMS (1.62 mm dia.)
Nominal Input Rating
20,100
-
30,000 BTU/hr
(5.9
-
8.8 kW)
23,000
-
30,000 BTU/hr
(6.7
-
8.8 kW)
P.4 Fireplace Efficiency (FE)
SIT 820:
65.94%,
SIT 821:
67.80%
P.4 Steady State Efficiency
SIT 820:
68.49%,
SIT 821:
68.49%
Electrical Rating
120 VAC, 60 Hz less than 2 A.
Altitude
0
-
4500 ft (0
-
1372 M)
0
-
4500 ft (0
-
1372 M)
Primary Air Opening
¼
” (6
mm) OPEN
½
” (13
mm) OPEN
HIGH ALTITUDE INSTALLATION
When installing this appliance beyond 4500 ft. (1372m) above sea level, the appliance must be properly de
-
rated and installed according to local codes; in the absence of local codes, with the current National Fuel
Gas Code, ANSI Z223.1/ NFPA.