31-DVIM33
20
Control access
behind trim
Care must be taken when accessing the controls while fireplace is active. Parts will be
HOT
SURROUND INSTALLATION
Surround options available are dependent upon the con-
trol panel configuration. (See Control Panel Locations
regarding configuration.) Shallow surround options are
not available on a unit with ‘Controls Out’ configuration.
Make sure the gas and electrical lines are properly con-
nected to the appliance. Slide the unit into the fireplace
and slide the excess flue liner material back onto the
chimney. Before the appliance is fully recessed into the
fireplace, attach the surround onto the appliance.
Attach the surround to the appliance at the locations
shown by lining up the tabs on the surround with the
slots on the unit. Make sure the surround drops down
and fully engages. Then finish with the wiring connection
to the on/off switch on the side of the trim. Now fully
“seat” the unit into its final position.
Surround Mounting slots
Surround Mounting
tabs
Restrictor installed
in upper baffle.
Center air channel
is closed off with
restrictor
Firebox baffle w/out
restrictor.
All three air channels
in the baffle are open
VENT RESTRICTOR INSTALLATION
When the vent is over 18’(5.5m) a vent restrictor may be required. The installation of the restrictor will equalize the vent
stack action that can cause problems with a proper fire set-up.
The vent restrictor is supplied loose in the manual bag. When required, it installs onto the upper baffle in the center portion.
The baffle air openings are located in the top of the firebox just inside the front frame of the fireplace. There are holes al-
ready in the standoffs that will line up with the holes in the restrictor.
Upper Baffle
air channels
Upper Baffle