31-DVIM33
17
CHECKING INLET AND OUTLET GAS PRESSURE
The pilot assembly is convertible to the type of
gas being used, simply unscrew the body by
using a 7/16” (11 mm) wrench turn a 1/4 open
then push the small metal tab across to the
other side of the body and retighten.
Call your
local Authorized Archgard Dealer to pur-
chase the correct fuel conversion kit for
your gas appliance.
CHECKING AND ADJUSTING PILOT
The pilot flame should have the characteristic
as shown in the illustration to the right. The
flame should not have yellow tips but should
engulf the thermocouple and thermopile. It
can be adjusted by turning the screw marked
“pilot” on the control valve.
7/16” (11 mm)
WRENCH
(HERE)
Thermopile
Burner Ports
1. Remove the surround.
2. The pressure test taps are located on the valve. The taps are located in the gas valve front face.
The inlet is marked ‘
IN
’
and the outlet is marked ‘
OUT
’.
See Fig.1.
3. Loosen the set screw inside the tap with a screwdriver.
4. Connect a 1/4” (6 mm) rubber tube to the tap post and a manometer.
5. Verify that the readings obtained are within specs (as shown on the appliance rating plate)
6. Be sure to tighten the set screw inside the tap after you have finished taking pressure readings.
7. Check for leaks.
OUT (manifold)
IN (inlet)
Thermocouple
Electrode