31-DVIM33
13
APPLIANCE DESCRIPTION
ELECTRICAL CONNECTIONS
The 31-DVIM33 comes complete with an variable speed fan.
Do not cut or remove the grounding prong from this plug.
NOTE: This appliance, when installed, must be electrically grounded in accordance with local
codes or, in the absence of local codes, with the
National Electrical Code, ANSI / NFPA 70
,
or the
Canadian Electrical code, CSA C22.1.
Before placing the appliance into the fireplace, check the hearth of the fireplace to see if it is level
with the front of the fireplace. If it is not, measure the depth of the hearth. Loosen the three
screws of the leveling “L” bracket at the back of the appliance. Lower it to the measurement
obtained and tighten the screws.
TOP VIEW
Fresh Air
Exhaust
FRONT VIEW
Ceramic
Glass with
standard
black door
frame
Surround
On/Off
Rocker
Switch
Control access
Care must be taken when accessing the controls while fireplace is active. Parts will be
HOT
LEVELING THE 31-DVIE33
Front Level
Located slightly in from the front edge of the fireplace is the new level-
ing feature. 1” Leveling bolts have been pre-installed to enable you to
raise the front of the firebox if necessary. If you need higher adjustment
you only need to change the 5/16” x 1” to a longer bolt as needed. If no
rise is required simply remove.
Rear Level