Mounting warnings: the piece with longer slots must be firstly positioned on the boiler back plate side.
The grate with longitudinal slots (pic. 1,2,3,4) is better suited with types of wood producing thinner ashes.
When changing the grate for wearing related issues, it is important taking into adequate account the kind of
wood usually used.
Warning: in function of the wood type used, its thermal power, the humidity degree and the average ash
dimensions, may be required a grate with different slots shape in order to prevent slots plugging.
Usually the two grates, the ones with longitudinal slots and the other ones with transverse slots ensure
similar thermal yields and powers. The transverse slotted grate (pic.5 and pic.6), is more suitable for very dry
wood with high thermal specific power, with bigger ash dimensions.
TRANSVERSELY SLOTTED BAR ELEMENTS
28
Fig.5
20
Fig.6
TRANSVERSELY SLOTTED BAR ELEMENTS
Models
Number of bar
elements
Code
29 4.5
BAR
0106T
43 5
BAR
0107T
52 7
BAR
0108T