![Arca Caldaie ASPIRO DUO TECH Installation Operation & Maintenance Download Page 45](http://html1.mh-extra.com/html/arca-caldaie/aspiro-duo-tech/aspiro-duo-tech_installation-operation-and-maintenance_2963444045.webp)
45
9.1.3. General connection diagram for heating only purposes - plate type heat exchanger
Key:
PI
System pump
V
Non return valve
PR
Bypass pump
S4
Heating system delivery temperature sensor
IR
Heating system
S5
Heating system return temperature sensor
SP
Plate heat exchanger
9.1.4. General connection diagram for heating only purposes - closed type expansion tank on the hot
sanitary water circuit (SA version)
Key:
PI
System pump
V
Non return valve
PR
Bypass pump
S4
Heating system delivery temperature sensor
IR
Heating system
S5
Heating system return temperature sensor
SCA
Coil type copper sanitary water heat exchanger.
Summary of Contents for ASPIRO DUO TECH
Page 2: ...2...
Page 17: ...17 6 2 Electronic board inside the electronic control panel...
Page 62: ...62...