![Arca Caldaie ASPIRO DUO TECH Installation Operation & Maintenance Download Page 25](http://html1.mh-extra.com/html/arca-caldaie/aspiro-duo-tech/aspiro-duo-tech_installation-operation-and-maintenance_2963444025.webp)
25
7.2. Pellet
operation
PHASE 1
−
Mount the upper door with the pellet burner.
−
Wire the burner cable to the electronic control panel.
−
Connect the flexible auger device tube to the burner fuel inlet (be sure that the flexible tube has a proper
inclination, without less inclined sections which may cause inconstant fuel feeding rate).
PHASE 2 -
MODULATOR ADJUSTING –
Before firing the pellet burner, be sure that the combustion air modulator device disc is completely closed. To
avoid deformations of the modulator device we recommend to extract the copper sensing part to avoid boiler
temperature sensing.