Flex 2JB-VRX Instruction Manual
June 2022 v1.0
Page 50 of 70
C N11
CN 17
F un ctio n3
CN11
CN17
Function3
OR
4.2.7 Voltage Settings
Always check the voltage setting is correct for your application prior to installation.
FUSE #
9~36VDC
24~48VAC
110~240VAC
380~460VAC
F3, F9 and F10
5.0A
5.0A
5.0A
5.0A
F1 and F2
3.0A
3.0A
1.0A
1.0A
4.2.8 Indicator Light and Buzzer Installation
The miniature indicator light and buzzer can be easily fitted onto the receiver enclosure. The
indicator light or the buzzer works simultaneously with the receiver MAIN relays (manufacture
preset). When receiver MAIN relays are activated the indicator light or the buzzer is also
activated, or vice versa. Make sure the indicator light or the buzzer is connected to the K30
Function output relay CN11 port located on the line filter/digital/analog mother board inside
the receiver. Please contact ARC representative if you would like the indicator light or the
buzzer work differently than described above. Refer to section 4.2.5 and section 4.2.6.6 ~
4.2.6.8 Function relay descriptions and programming