4.2.5 Function Relay Outputs
Listed below are other types of functions that can be outputted through the three Function output
relays (K25, K26 and K30). Refer to section 4.2.6.6 ~ 4.2.6.8 function relay programming.
LV
:
Function relay closes when receiver voltage is low.
ID
:
Function relay works simultaneously with all motion commands.
NORMAL :
START fu AUX with normal momentary output. Works the 2
nd
time
the START button is pressed.
NORMAL2 :
START fu AUX with normal momentary output. Works the 1
st
time
the START button is pressed.
TOGGLE :
START fu AUX with toggled output.
TOG&E :
START fu AUX with toggled output. The relay opens when STOP
button is pressed down.
EXT
:
Function relay works simultaneously with the receiver MAIN relays.
TDM A+B :
Function relay closes when selector switch is rotated to the A+B position
and opens when rotate to A or B positions (tandem monitoring output).
HORN
:
Function relay closes for up to 3 seconds when START button is pressed
at transmitter power on and then becomes a normal momentary output
thereafter.
G SENSOR :
Function relay closes when Zero-G sensor is triggered (receiver MAIN
relays deactivated) and opens when receiver MAIN relays are reactivated.
RESET
:
Function relay closes when the START button is pressed and opens when
let go. Works during initial transmitter startup and inactivity timer START
reset.
SW1 ABC
:
Function relay closes at C position (for button or toggle switch programmed
to Select A/B/C function).
SW2 ABC
:
Function relay closes at C position (for button or toggle switch programmed
to Select A/B/C function).
SW3 ABC
:
Function relay closes at C position (for button or toggle switch programmed
to Select A/B/C function).
SW4 ABC
:
Function relay closes at C position (for button or toggle switch programmed
to Select A/B/C function).
SW7 ABC
:
Function relay closes at C position (for button or toggle switch programmed
to Select A/B/C function).