C3/D1: setup electrical connection accor
-
ding to the diagram Fig. E1 (protection class
I) or E2 (protection class II).
•
Designation of the wires:
–
L = phase (brown)
–
N = neutral (blue)
–
PE = protective conductor (green / yel
-
low)
–
FP = fil pilote (black) (on-site)
►
C4: before installing the cover, set the ope
-
rating mode according to Fig F1-F3 if neces
-
sary.
Setup of the operating mode
In the as-delivered condition, the thermostat
is programmed for regulating the room tem-
perature. If a regulation independent of the
room temperature of the radiator tempera-
ture is desired (e.g. because the room tempe
-
rature is regulated via panel heating), execute
the following steps according to Fig. F1-F3:
►
Remove the frame, the dial (2) and the tem
-
perature controller (1) carefully.
►
Set the rotary switch (7) to the "1" position.
–
LED (4) mode displays the conversion by
blinking yellow.
Display of the operating mode goes out.
–
Towel warming mode is active.
►
Attach the frame, the dial (2) and the tem
-
perature controller (1) again.
If regulation of room temperature is desired
instead of towel warming, repeat the above
mentioned steps. For this, set the rotary switch
(7) to the "0" position. The LED (4) mode dis
-
plays the conversion by blinking red.
Position of the rotary switch (7):
•
"0" = Room temperature regulation mode
•
"1" = towel warming mode
Display of the set mode
►
Keep the boost button (3) pressed for ap
-
proximately 10 seconds.
–
LED display (4) blinks red –> room tem
-
perature regulation mode
–
LED display (4) blinks yellow
–> towel warming mode
–
Display of the operating mode goes out.
–
The thermostat is ready to operate.