2 Installing the Compressor
6
Loosen the manifold bolt (10mm socket) and rotate the outlet port to the desired position.
Figure 5.
Retighten the manifold bolt (10mm socket) to approximately 9 Nm [6.6 ft-lb].
Refit the cover reversing the above operations.
NOTE : Polarity isn't important when reconnecting the pressure switch connectors.
NOTE : Retighten the four cover bolts (10mm socket) to 6 Nm [4.4 ft-lb].
2.3 Drilling & Mounting the Compressor
Establish the mounting hole locations for the compressor from the mounting bracket drill
template Fig. 6.
NOTE : For greater mounting flexibility eight mounting nuts are provided in the
mounting bracket but only four must be used. Choose one hole from each
pair (A, B, C, D) shown in Fig. 6, to best suit your installation location. This
will ensure that the weight of the compressor is well distributed.
Drill four mounting holes at a diameter of 8mm [5/16 inch].
NOTE : Try to drill mounting holes accurately. Holes should never be drilled open to
more than 10mm [3/8 inch] in size to compensate for misalignment.
Assemble the hex bolts and washers from the opposite side, through the newly drilled
hole in the panel and into the nuts in the mounting bracket.
Tighten to a torque of approximately 6 Nm [4.4 ft-lb].
ROTATE THE MANIFOLD
CAP INTO
THE DESIRED
POSITION
LOOSEN
MANIFOLD BOLT