background image

 

Page 8

 

 

1.1.2

 

Aranet PRO indicators

  

  

  

  

(1)

 

Sensor data indicator LED – flashes amber every time a data packet is received from a sensor.  

(2)

 

Wi-Fi connection indicator LED – amber light when Aranet PRO is connected to Wi-Fi or works in 
Access Point mode  

(3)

 

LAN connection indicator LED – amber light when Aranet PRO is connected to LAN connection through 
an Ethernet cable  

(4)

 

12V power indicator LED – green light when Aranet PRO is connected to 12V power either through a 
PoE connection or with the included AC power adapter  

(5)

 

Battery power indicator LED – red light when Aranet PRO is using built in backup battery power  

 

 

 

 

 

 

 

 

 

 

Summary of Contents for PRO

Page 1: ...USER GUIDE Aranet PRO Aranet PRO Applicable for Aranet PRO Aranet PRO with firmware starting from v 3 0 1 Document revision v 9 July 2022 ...

Page 2: ...rent from the one the receiver is connected to Consult the dealer or an experienced radio TV technician for help Changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment Aranet PRO PRO does not contain serviceable parts Warranty will not be applicable in the event of Aranet PRO has been opened or Aranet PRO war...

Page 3: ...e including interference that may cause undesired operation of the device Le présent appareil est conforme aux CNR d Industrie Canada applicables aux appareils radio exempts de licence L exploitation est autorisée aux deux conditions suivantes 1 l appareil ne doit pas produire de brouillage et 2 l utilisateur de l appareil doit accepter tout brouillage radioélectrique subi même si le brouillage es...

Page 4: ... in Wi Fi Access Point 17 2 1 2 Initial setup of Aranet PRO Aranet PRO using Ethernet cable 18 2 1 3 Initial Login and Fast Settings 19 2 2 Pair sensors to Aranet PRO PRO 23 2 3 Connecting Aranet PRO PRO to internet network 26 2 3 1 Connecting Aranet PRO PRO to internet network using local Wi Fi router 26 2 3 2 Connecting Aranet PRO PRO to internet network using external router 28 2 4 Accessing th...

Page 5: ... 4 Stem Micro Variation sensor 72 4 1 5 Ultrasonic Distance sensor 75 4 1 6 CO2 and Temperature sensor 76 4 1 7 Pulse Counter sensor 76 4 1 8 NH3 Sensor kit 77 5 LEGAL INFORMATION 78 5 1 TERMS OF USE 78 5 2 WARRANTY 78 5 3 RMA RETURN MERCHANDISE AUTHORIZATION FORM 80 5 4 INTELLECTUAL PROPERTY RIGHTS 81 5 5 DATA SECURITY 81 5 6 CLEANING AND MAINTENANCE 81 5 7 ACCESSORIES 82 5 8 DISCLAIMER 82 5 9 AD...

Page 6: ... use interface allows viewing analyzing and comparing data in real time setting thresholds for alarms as well as exporting reports Responsive design of the software adapts to smartphone tablet or laptop Document describes the functionality of Aranet PRO Aranet PRO with firmware version starting v3 0 1 Aranet PRO and Aranet PRO differences in hardware and software are highlighted in corresponding c...

Page 7: ... What s in the box 1 1 pc of Aranet PRO base station with installed Aranet SensorHUB software and License 2 1 pc of Aranet PRO base station mount 3 2 pcs of W1412 screws 4 1 pc of AC power adapter EU or US version depending on product version ...

Page 8: ...d to Wi Fi or works in Access Point mode 3 LAN connection indicator LED amber light when Aranet PRO is connected to LAN connection through an Ethernet cable 4 12V power indicator LED green light when Aranet PRO is connected to 12V power either through a PoE connection or with the included AC power adapter 5 Battery power indicator LED red light when Aranet PRO is using built in backup battery powe...

Page 9: ...t PRO is turned off switch in the right position means Aranet PRO is turned ON 2 AC Power port for using the included AC power adapter to power Aranet PRO 3 Ethernet port for LAN connectivity as well as PoE connectivity 4 Reset button press and hold for 5 seconds or more and then release the button to reset network settings and password of root user account The reset button is accessed through hol...

Page 10: ...nd allows Aranet PRO to shut down safely System warning if enabled will be issued in case of main power failure and before Aranet PRO switches off completely Warning will be sent as email and or SMS to the destination configured by users belonging to the Administrator group WARNING ARANET PRO BASE STATIONS CONTAIN A LI ION 14500 PROTECTED TYPE RECHARGEABLE BATTERY AND A CR2032 TYPE BATTERY RISK OF...

Page 11: ...Page 11 1 2 ARANET PRO BASE OVERVIEW 1 2 1 What s in the box 1 2 1 1 pc of Aranet PRO base station with installed Aranet SensorHUB software and License 2 1 pc of Cat 5 Ethernet cable 1m ...

Page 12: ...curing Aranet PRO case lid 4 pcs 3 Warranty seals Nylon screws 4 pcs Warranty is lost if damaged 4 SIM card holder P N TDSBOB03 TDSBOBU3 TDSBOBC3 only 5 Network Reset button press and hold for 5 seconds or more and then release the button to reset network settings and password of root user account 6 Humidity membrane Do not unscrew ...

Page 13: ...i Fi connection indicator LED yellow light when Aranet PRO Wi Fi network interface is enabled and base is connected to Wi Fi or works in Access Point mode 4 Ethernet connection indicator LED yellow light when Aranet PRO is connected to LAN using cable 5 System indicator green light when Aranet PRO system is started 6 Power indicator LED green light when Aranet PRO is powered 1 2 4 Aranet PRO mount...

Page 14: ...t orientation 7 Flip cover back and fasten it by rotating metal locking plate clockwise 8 Put back Aranet PRO lid and fasten 4 screws 1 2 6 Aranet PRO power options Aranet PRO is powered by 802 3af PoE directly from the PoE enabled Ethernet switch or using optional PoE insert 1 2 7 Emergency switching off Aranet PRO can shut down and switch off safely in case of main power failure System notificat...

Page 15: ...s US920 Channel 1 917 3 922 9 MHz Channel 2 917 5 923 1 MHz Channel 3 917 7 923 3 MHz Channel 4 917 9 923 5 MHz Channels Russia RU869 Channel 1 868 85 MHz N A Channel 2 869 05 MHz N A Channels Asia AS923 Channel 1 923 1 MHz Channel 2 923 3 MHz User interface Aranet SensorHUB Interface accessibility PC tablet or smart phone connected via Ethernet cable or local Wi Fi connection Interface languages ...

Page 16: ...ions 107x170x26 mm 4 2 6 7 1 02 in w o mounting bracket 180 x 120 x 45 mm 7 09 x 4 72 x 1 77 in Ports 12VDC power port 1 x Ethernet 1 x USB A 1 x Ethernet SIM card N A 1 x Mini size N A Weight 190g 6 7oz w o mounting bracket 250 g 8 8 oz Construction ABS Plastic steel mounting bracket PC plastic Protection class IP42 IP67 CE FCC IC Marking Yes CE Included AC DC power adapter mounting bracket Cat 5...

Page 17: ...tial setup of Aranet PRO PRO using built in Wi Fi Access Point Aranet PRO Aranet PRO setup using built in Wi Fi Access Point is the easiest way to start working 1 Aranet PRO Plug in Ethernet cable connected to powered PoE insert OUT terminal or PoE enabled switch Wait until LED indicators Power System and Wi Fi turn On Aranet PRO Plug in included AC power adapter jack and switch base on using On O...

Page 18: ... 3 Initial Login and Fast Settings of this manual 1 Aranet PRO Plug in Ethernet cable connected to powered PoE insert OUT terminal plug another Ethernet cable to PoE insert IN terminal and connect it directly to your PC Wait until LED indicators Power System and Ethernet turn On Aranet PRO Plug in included AC power adapter jack and switch base on using On Off switch plug in Ethernet cable that con...

Page 19: ...parate accounts for users as required There are two levels groups of access user and administrator User group accounts have read only permissions can only view parameters and can subscribe to notifications The total account limit is 20 including root account After entering Username Password and clicking LOGIN button for the first time following page will open Now you can change the regional networ...

Page 20: ...a good practice to start with System settings Click with your mouse to the Menu icon to open MAIN menu and select System Navigate to Region menu and set your preferred Language Units Time and Data formats Click Save ...

Page 21: ...o Firmware menu It is highly advised to install the latest firmware for your Aranet PRO PRO base Visit aranet com downloads to download the latest firmware version and upgrade your device if it has older firmware version installed Refer to this document chapter 3 6 5 Firmware menu for upgrade instructions ...

Page 22: ...d near to your location Be patient it is long lasting process and can take up to 3 hours You can skip scanning by now and select channel at your desire but this can lead to less good communication between sensors and Aranet PRO PRO base NOTE Keep in mind you will have to repeat all sensors pairing process if you decide to change radio channel You can leave System menu now and switch to Sensors men...

Page 23: ...rn clockwise the main plastic body of the sensor do not remove or twist the cable Most other sensors have visible battery compartment or screws on the body Loosen the screws to take out the lid and expose battery compartment Take out battery ies from the sensor s you want to pair If there are two batteries in the battery compartment it is enough to take out one 2 Log in to Aranet PRO PRO web inter...

Page 24: ...display successfully paired sensor in the sensors list new sensors are indicated by green triangle Sensor pairing process usually lasts 10 15 seconds but can be prolonged up to 30 seconds Each time new sensor is successfully paired 2 minutes timer is restarted If sensor pairing was not successful within 30 seconds period take out battery from the sensor wait 10 seconds and place battery back to re...

Page 25: ...Page 25 You have now paired sensors to Aranet PRO PRO and can place it in the desired location All paired sensors appear on the Home page of SensorHUB The fast set up process is finished ...

Page 26: ... on Aranet PRO in following way 1 Connect your PC to Aranet PRO PRO using Ethernet cable refer to chapter 2 1 2 Initial setup of Aranet PRO PRO using Ethernet cable 2 Navigate to SYSTEM NETWORK and select WIFI tab 3 Choose the Client mode see picture below 4 Under Select from this list or input manually find name of your local Wi Fi network 5 Choose the required Encryption 6 Fill in the Wi Fi pass...

Page 27: ...he new IP address displayed like shown in picture below Wi Fi IP xxx xxx xxx xxx Note the globe symbol is not crossed which indicates successful connectivity to the Internet 9 Disconnect Ethernet cable 10 Make sure your PC and Aranet PRO PRO are connected to same Wi Fi network 11 In browser type the new IP address Wi Fi IP xxx xxx xxx xxx and login to Aranet PRO PRO ...

Page 28: ... LAN port using Ethernet cable 3 Verify that LED indicators next to 12V and LAN turn on 4 As factory setting Aranet PRO PRO DHCP client is ON If there is working DHCP server in the network as usually is when connecting to router Aranet PRO PRO will receive new IP address automatically While connected to Aranet Wi Fi you can verify new Ethernet IP address assigned by external router like shown in t...

Page 29: ...ccasions when the DHCP server s assigned IP address for Aranet PRO PRO Ethernet port is changed Consult your network administrator or refer to the user manual of the external router on how to always reserve the same IP address assigned to the Aranet PRO PRO Ethernet port MAC address ...

Page 30: ...r router to setup an access to Aranet PRO PRO Port forwarding is configured on your router Refer to the User Guide of your router on how port forwarding should be configured Below is example of possible configuration For accessing Aranet PRO PRO open the Internet browser and in URL bar type the IP address with port number xx xx xx xx port nr for instance 213 100 100 1 8100 These were the main step...

Page 31: ...s Each user account has its own favorite list The alarm icon allows you to quickly see a list of all sensors that have current alarms and may need attention 3 2 Main menu Main menu contains following sections Home Graph Sensors Groups System MQTT Aranet Cloud Modbus TCP IP From these sections you can navigate to all options of the Aranet PRO PRO software General information about the user login cu...

Page 32: ...ecting respective sensor a submenu opens with sensor information sensor serial number type name group thresholds last time data was received battery level signal strength All changes for sensor settings can be adjusted here Selecting Graph icon will open Graph screen for respective sensor Favorite icon enables a user to add remove the sensor as a favorite Notification delay allows the user to defi...

Page 33: ...0 sensors at once for analysis one by one or use icon to add first 20 sensors at once 2 Choose which values to graph depending on the attached sensor and receive as much information as needed 3 Set custom period to look for historic data analysis 4 Export data to xlsx csv png or svg files by using Download button Use Tune button to open a sub menu allowing user to select or deselect additional par...

Page 34: ...while scrolling the mouse wheel On a smartphone device it is possible to use multi touch and panning function with two fingers for navigation Positioning the cursor on specific point on the graph detailed information about measurement reading will be displayed If you wish to highlight some sensor s data in the graph click on the sensors name The graph line of the selected sensor will be highlighte...

Page 35: ...nularity untick the Autoscale and choose the Min and Max values by moving the slide bars or typing in the required values To rearrange the order in which the graphs are displayed drag the parameter boxes by the Move handle Release it in the desired position ...

Page 36: ...roups can have names that represent for instance their type location room etc As well as set alert thresholds and choose different alarm types applicable for whole group Maximum number of supported groups is 20 3 5 1 Using groups 1 You should be logged in using an account with administrative rights 2 To create a new group go to Aranet PRO PRO Main menu and choose the Groups menu 3 Click Add group ...

Page 37: ...main menu Home 6 In sensor options click on the group drop down menu Choose the group you would like to add this sensor to 7 In sensor options it is also possible to toggle between sensor thresholds and group thresholds as preferred so even grouped sensors can have individual thresholds 8 Click the Save button to save changes ...

Page 38: ...ion screen that will provide you with information about the Aranet PRO PRO You can change the name of the Aranet PRO PRO device by clicking on the pencil sign and typing in the new name and confirming the change with the SAVE button Aranet PRO PRO device name will be used in the email notifications for easier identification of which Aranet PRO PRO device is sending the message ...

Page 39: ... Region menu The Regional settings menu is where the interface of Aranet PRO PRO can be set up with the preferred language temperature scale and time and date format settings To apply new settings click Save button ...

Page 40: ...n NTP server for time synchronization NTP time synchronization requires connectivity with Internet refer to chapter 3 6 4 Network menu NOTE If device time is adjusted backwards any data previously gathered with a timestamp later than the newly set time will be discarded and permanently lost It is recommended to enable NTP time synchronization if Aranet PRO PRO is registered to Aranet Cloud ...

Page 41: ...Aranet PRO base owner separately 3 6 4 1 WIFI menu By default Aranet PRO PRO is configured as a Wi Fi Access Point for easy initial configuration However if you wish this can be changed The first menu screen is for the Wi Fi setup where you can choose between Access Point and Client connectivity Factory settings of Aranet PRO PRO Wi Fi interface are Wi Fi interface configured as Access Point o SSI...

Page 42: ...e Wi Fi connection and fill in the Wi Fi password Apply the changes by Save button NOTE Most routers have DHCP enabled by default we recommend keeping this setting for ease of set up For advanced users however static IP address set up is possible Globe symbol with no crossover indicates successful connectivity to network ...

Page 43: ...PRO did not receive IP address from DHCP server last settings entered in IP address Subnet mask Default gateway and DNS server fields are applied If no settings were entered before default Factory settings are in force The same settings are in force after NETWORK RESET If Static IP fallback is switched OFF no valid IP address is assigned to Aranet PRO PRO Ethernet interface when it did not receive...

Page 44: ...use additional expenses not covered by Aranet PRO manufacturer Please consult your Mobile Internet provider for data to fill out connection configuration fields It is possible to access Aranet PRO web interface from internet over LTE connection For this purpose please contact your Mobile Internet provider and request static IP address for the SIM card inserted into modem NOTE Connection configurat...

Page 45: ...ate is possible too For semi automatic firmware update Aranet PRO PRO must be connected to internet When navigating to this menu Aranet PRO PRO connects to SAF Tehnika server over HTTPS protocol TCP on port 443 to check for newer firmware version availability If newer firmware version is released notification is shown If the base is not connected to internet the error message is displayed ...

Page 46: ...to the subversion only I e downgrade from v 3 x x is not possible to v 2 x x downgrade is possible from v 3 x x to v 3 y y Firmware upgrade file name should not be changed as it might not be recognized otherwise The software update usually takes about two minutes to be completed During that period the device will reboot to complete the update After the firmware upgrade if the Aranet PRO PRO web in...

Page 47: ...ed in the backup file if you duplicate clone the base station current Aranet PRO PRO name will be overwritten with imported one 3 6 7 Tools menu Aranet PRO PRO base management options such as remote reboot network reset full factory reset and diagnostics file download are available here REBOOT reboots the Aranet PRO PRO NETWORK RESET will load the default network settings for Aranet PRO PRO and ca...

Page 48: ...for each individual user account Each user account can have different notification settings like summary alarms e mail and phone number for SMS delivery 3 6 9 1 Sensors screen The first Sensors screen shows groups of sensors and allows you to choose individual settings for each group 1 Click icons to receive alarms for thresholds crossed summaries or both 2 If sensors are not added to any group th...

Page 49: ...fication please start with configuring the E MAIL which notifications will be sent from Then proceed back to SETTINGS to specify email address where notifications will be sent to 1 Input your email address and phone number to receive the notifications 2 Save changes once you have completed all tasks 3 It is suggested to perform a test of notifications by using the TEST SENDING button located at th...

Page 50: ...Page 50 ...

Page 51: ...e Humidity CO2 Pressure Voltage Current Packet loss in percentage with missing packet count and the maximum number of packets lost in a row Temperature Humidity CO2 Pressure Voltage and Currentalarms when a threshold was crossed above or below and its duration Name of the sensor and name of group it belongs to Battery warnings Channel warnings in case a sensor is using a different radio channel th...

Page 52: ...for modem to stabilize Status OK indicates that modem is ready During initializing the status might change several times Following messages will indicate status of modem GSM modem not connected GSM modem is not connected or is not recognized Re insert the modem and allow it to stabilize Modem did not accept this PIN indicates that entered PIN code is incorrect Enter correct PIN code Fault descript...

Page 53: ...net via Wi Fi Some email service providers like Gmail requires enabled 2 step verification Using Customer SMTP as E mail service provider consult with the provider for appropriate SMTP settings to use It is advised to check whether notification e mails do not end up in spam folder Other typical messages about connectivity E mail server reached successfully connectivity with SMTP server is ok Conne...

Page 54: ...hannel or all channels at same time Scan takes 60 minutes per channel during which it is not possible to pair new sensors to the base station or change the time of device Channel switching is disabled during the scan Some data may be lost during the scanning period You can abort the scan process by selecting STOP SCAN The statistics of scanned channel in this case will be lost After scan we recomm...

Page 55: ...elow on how Aranet MINI can be reconfigured to its default standalone mode There are two ways to configure Aranet MINI to work in monitor mode 3 6 11 1 Using a computer 1 To configure Aranet MINI into monitor mode you need to log in Aranet PRO using a desktop PC and choose the Monitor mode in System settings menu submenu Aranet Mini 2 Select the firmware version of Aranet MINI you will be using as...

Page 56: ...O using a desktop PC or a smart device and choose the Monitor mode in System settings menu submenu Aranet Mini 2 The firmware version of the Aranet MINI will be detected automatically once it is connected to Aranet PRO PRO You do not need to select the version manually 3 Choose the sensors you wish to display on Aranet MINI up to 12 sensors by selecting the buttons Here you can change name of the ...

Page 57: ...ly be given to those who need features such as software update network reset threshold settings etc By default root account in Administrator group is provided Root account cannot be deleted nor its name changed Root account can modify other user accounts belonging to Administrator and User groups Up to 20 accounts can be created including root NOTE Change the root user password Default password is...

Page 58: ...SAF ENTERPRISE MIB SAF ARANET PRO MIB and additional trap event type and severity level definitions related ITU ALARM TC MIB IANA ITU ALARM TC MIB MIB files can be downloaded here Current Aranet PRO PRO SNMP agent implementation supports read only mode on OID request processing Max 5 SNMP managers IP v4 addresses and max 5 trap managers IP v4 addresses can be added ...

Page 59: ...RO PRO as MQTT publisher it is necessary to have A software application which can make data requests and receive data in MQTT format subscribe to MQTT data reception for example account on Amazon AWS or Microsoft Azure cloud computing platforms Access to some MQTT broker that is necessary to obtain data from Aranet PRO PRO base station and then send it to the user software A valid MQTT license fil...

Page 60: ...ssages will be published from Aranet PRO PRO base station on MQTT broker In our example we will use the name Aranet 8 Sensor measurement format allows selecting format raw JSON or Azure in which MQTT messages from Aranet PRO PRO base station will be published on MQTT broker 9 Encryption upon necessity allows configuration of additional encrypted certificates TLS version 1 1 1 2 or 1 3 to be used f...

Page 61: ...y pressing the blue Save icon If configured MQTT connection is successful then Connection successful message will be shown on the top of the page also showing the precise time when the connection was established For more MQTT connections settings examples refer to https aranet com software ...

Page 62: ... locations Every organization can set up trial Aranet Cloud account with access for a period of 30 days Before setting up an Aranet PRO PRO base station on the Aranet Cloud platform a couple of things should be verified and provided User has any type of device with a working Internet connection and WEB browser installed on it User has access to an e mail account that can be used for new account re...

Page 63: ...be green and type in or paste from clipboard e mail address you are registered with in aranet cloud and generated registration code 5 Click REGISTER TO THE CLOUD New webpage will open informing about registering result Reload page to see information about cloud connection state If Cloud service is unavailable and icon is red then check base Internet connection ...

Page 64: ...nd Aranet Cloud system can take up to 20 30 minutes During this process sensor data will gradually appear in the Aranet Cloud organization You can pause uploading sensor data by switch off Enable cloud upload If you wish to unregister Aranet PRO PRO base from cloud click UNREGISTER FROM THE COUD For more information about Aranet Cloud refer to Aranet Cloud User guide For Aranet Cloud usage guideli...

Page 65: ...will be replied o In case if unavailable registry address is being requested message with ILLEGAL_DATA_ADDRESS code will be replied This exception is sent also in case if address is colliding with any other registry address o In case if uninitialized registry address is being requested message with ILLEGAL_DATA_VALUE code will be replied Address of the registry exists but valid data of measurement...

Page 66: ...nteger or float value Data type also determines the registry size needed to encode the value into bytes Size of two bytes is used for a single Modbus registry The selected data type also affects an offset value for the next measurement address e g if temperature s 1 data type is float then next measurment offset value must be 3 as temperature measurement offset is 1 and it s data type length is 2 ...

Page 67: ... rssi in dBm offset 6 dataType int32 multiplier 1 time Address 28 measurement time in seconds offset 8 dataType uint32 multiplier 1 Autogenerated file can be used as template for Custom layout file creation you can edit it to read needed sensors and measurements only ...

Page 68: ...the TARE button The last measured tared and untarred weight as well as the date and time of the last tare event will be indicated By default the graph of the Weight Sensor will display measurements of a tared weight To display the untarred weight in the graph click the Tune button and tick the Show box ...

Page 69: ...bration of the VWC and EC pore water calculation method by selecting Topp Soilless Mineral Soil or Rockwool Should you require to modify the calibration curve change the required calibration values If any of the preset calibration values are changed the method type will be change to Custom The calibration formula is expressed as a polynomial VWC a b ε c ε2 d ε3 e ε4 f ε5 g ε0 5 where ε is the appa...

Page 70: ...The graph of soil sensors by default displays Temperature Volumetric Water Content and Pore Electrical Conductivity Use the Tune button to display the Bulk Electrical Conductivity and dielectric permittivity ε ...

Page 71: ...cer type connected to mA V Sensor If required switch the Conversion on and use the drop down menu to choose a predefined Dimension and Unit If the required Dimension or Unit is not in the list choose Other as the Dimension and input your own measurement unit Define the reference values for two measurement points i e sensor s min max voltage For example set 0 V equal to 100 of your units and 32V eq...

Page 72: ...n installation The process can be done in the following steps 1 First existing stem diameter should be measured with a ruler or caliper in our example 8mm 2 Then sensor detecting element should be mounted on the stem 3 Sensor electric current reading on Aranet PRO base station graphical user interface should be checked and recorded in our example 5 12mA ...

Page 73: ...nd it is the measurement range used by the sensor in millimeters in our example 0 35mm 7 Next the used measurement range in millimeters should be subtracted from stem diameter measured in point 1 in our example 8mm 0 35mm 7 65mm and here we obtain stem diameter value that corresponds to 4mA electric current reading of the sensor 8 Then measurement value in millimeters should be determined that cor...

Page 74: ...Page 74 ...

Page 75: ...r works with a wide range of liquid and non liquid materials Various practical applications of the sensor include measuring grain level in a silo or the level of a liquid in a container as well as other uses When pairing Ultrasonic Distance sensor it is possible to set measurement thresholds and reference point if needed Enable conversion switch and select Units from drop down list Then enter Zero...

Page 76: ... environment during the calibration process for 30 minutes without any person nearby 5 When the calibration process is finished screw on the sensor s top part back 4 1 7 Pulse Counter sensor The sensor counts the number of mechanical contact closes The applications include electricity meters water flow monitoring etc Both count per measurement interval and the cumulative count are registered The S...

Page 77: ...kage of ammonia gas and give an alarm to protect humans and animals Kit consists of DOL53 sensor wire junction box TDADCA01 and Aranet 0 10 VDC transmitter Sensor and transmitter are connected to junction box which is powered by 220 240 VAC In addition Aranet 0 10V transmitter is powered by 1 AA size battery Connection scheme if following ...

Page 78: ...ions including frequency range of the customer s home country or jurisdiction WARRANTY TERM The Warranty shall apply to Aranet 24 months after it is shipped to the customer An invoice itemizing a product s warranty period shall be included with the product when it is delivered to the customer No verbal extensions or modifications of the Warranty shall be enforceable WARRANTY LIMITATIONS The Warran...

Page 79: ... of US and Canada may require Restocking and Refund within 60 days from the date of payment No Restocking and Refund will be available after the term of 60 days has passed If the Restocking is accepted by SAF the product s must be returned unused condition as brand new without any defects without dirt and scratches containing all original labels full completion as received in original package as r...

Page 80: ...Return Costs If a given product is covered by the Warranty SAF will pay the shipping costs associated with returning it to the customer If a product is outside of the Warranty the customer shall pay all costs associated with transmitting it to and from SAF An estimated cost of return will be included in any repair invoice sent to the customer and must be paid before SAF will return a repaired prod...

Page 81: ...he product 5 5 DATA SECURITY Aranet systems use encryption when the data is transmitted from the sensors to the base station A unique encryption key is provided for each base station The transmission protocol has built in safeguards against malicious operations for example replay attacks Aranet sensors are protected from unauthorized data collection therefore even if sensors are accessed the softw...

Page 82: ...his manual are provided as is Except as required by applicable laws no warranties of any kind either express or implied including but not limited to the implied warranties of merchantability and fitness for a particular purpose are made in relation to the accuracy reliability or contents of this manual To the maximum extent permitted by applicable law in no event shall SAF Tehnika JSC be liable fo...

Reviews: