PRELIMINARY SETUP FOR USE
Set the value of the flowmeter constant on the device connected to the ORION X flowmeter:
24 pulses/liter
91 pulses/gallon
For any reference on constant setting modes, refer to the use and maintenance manual provided with the device used.
6
USE
6.1
LED on the ORION X flowmeter
A multi-color LED positioned at the back of the flowmeter indicates the device status:
OFF
The flowmeter is not powered.
GREEN
BLINKING
The flowmeter is waiting to acquire an address on the
CAN line to which it is connected.
GREEN STEADY
ON
Presence of
STILL
liquid inside the flowmeter.
BLUE STEADY
ON
The flowmeter is reading the passage of the liquid
inside.
VIOLET STEADY
ON
No liquid has been detected inside the flowmeter.
WHITE STEADY
ON
Cleaning of the reading electrodes in progress.
RED BLINKING
RED: Error. The error codes are indicated through
blinks, which are described in the table below.
RED STEADY ON
SEVERE ERROR
: contact a service center.
Signals that can be managed are described in Chap.8, page 11.
The ORION X flowmeter is able to detect only the passage of conductive liquids with a conductivity equal to or greater than 300 μS/cm - Use
the flowmeter only within the flowrate limits set forth in the “Technical Specifications” table. Outside this range, the flowmeter may provide
incorrect data, thus misleading the operator or the automatic system.
ARAG can not be held responsible for any damage caused to persons, animals or things from the incorrect or unintended use of the
flowmeter or its parts.
6.2
Use of the keys (ORION X VISUALFLOW)
0.0 l
2
1
0.0 l/min
• Turning ON / OFF
• Quitting a menu or an item
• Data confirmation
• Scrolls among the menu items
• Scrolls among the dig-
its of the selected line
+
• Access to setup
menu