ELECTROMAGNETIC FLOWMETER

INSTALLATION, USE AND MAINTENANCE

VISUALFLOW

Summary of Contents for orionX

Page 1: ...4629XXXX ELECTROMAGNETIC FLOWMETER INSTALLATION USE AND MAINTENANCE VISUALFLOW...

Page 2: ...otalizer reset 9 6 6 Use for tank filling function 10 7 MAINTENANCE 11 8 ERRORS TROUBLESHOOTING 11 9 TECHNICAL DATA 12 9 1 Dimensions 12 9 2 Performance 12 9 3 Display 12 9 4 Electrical features 12 9...

Page 3: ...NOT BE USED TO MEASURE THE PASSAGE OF HYDROCARBONS FLAMMABLE EXPLOSIVE OR TOXIC LIQUIDS THE FLOWMETER IS NOT SUITABLE FOR CONTACT WITH LIQUIDS FOR HUMAN CONSUMPTION USE FOR SALES TRANSACTIONS IS NOT...

Page 4: ...length is at least 10 times the inner diameter of OrionX 75mm x 10 750 mm Install the flowmeter far from the elements that could cause turbulence inside the pipe valves bends bottlenecks etc It is re...

Page 5: ...fittings and on pipes For the connections use pipes and fittings duly dimensioned for system operating pressure MAX 5 bar Hose tails must be tightened with special metal clips ensuring a perfect seali...

Page 6: ...reading electrodes in progress RED BLINKING RED Error The error codes are indicated through blinks which are described in the table below RED STEADY ON SEVERE ERROR contact a service center Signals th...

Page 7: ...so generates the pump stop signal Menu Description Operator Manager Technician 1 Sensor Settings Min flowrate Threshold Minimum flowrate under which the output signal will no longer be generated The v...

Page 8: ...nsor name Name of the sensor display only l l l 23 Diagnostics Sensor properties Serial number Sensor serial number display only l l l 24 Diagnostics Sensor properties Hardware version Sensor Hardware...

Page 9: ...izer reset To reset a totalizer you must view it in extended mode Press key several times until value to be reset is at the central area of the display Press the key for two seconds Totalizer resets S...

Page 10: ...ave changes or D Press to quit the page without confirming changes 3 Keep key pressed for two seconds Filling starts The display shows the following data top part set filling quantity central part par...

Page 11: ...supply voltage too high or too low Check the power supply voltage and restore the correct value Unstable reading 5 Unstable reading Check that the flow is normal and make sure to have complied with th...

Page 12: ...m3 h Filling mode Yes Volume counter mode Yes Partial totalizers 2 9 4 ELECTRICAL FEATURES Power supply voltage 9 16 Vdc Maximum absorption 300 mA Protection against polarity inversion Yes Protection...

Page 13: ...t 906 1670 g according to the type Flange T9 Coupling Clamp Coupling 3 Full Port 9 7 MATERIALS Electrodes Stainless steel Aisi 316 Rings Stainless steel Aisi 316 Body fiber glass reinforced PA 6 Pipe...

Page 14: ...lters nozzles etc anything that can be considered to be normal wear and tear 3 Repairing the apparatus will be carried out within time limits compatible with the organizational needs of the Assistance...

Page 15: ...Notes 15...

Page 16: ...ilia ITALY Tel 39 0522 622011 Fax 39 0522 628944 www aragnet com info aragnet com Only use genuine ARAG accessories or spare parts to make sure manufacturer guaranteed safety conditions are maintained...