Electric connections

The Orion 2 flowmeter has been designed to be connected to ARAG devices (computers, screens, displays) but can also be connected to equipment 
made by other manufacturers as long as they are designed for flowmeters of this typology.

ARAG is not liable for damage to the system, persons, animals or things caused by incorrect or inadequate installation of the 

flowmeter. In the event of damage to the flowmeter, caused by incorrect or unsuitable assembly, any form of guarantee is auto-
matically rendered null and void.  

Color

Position

Connection

Black

1

GND

Red

2

+12 VDC

Green

3

Signal

(square wave)

2.4 

Hydraulic connections

For connection to the system, use appropriate fittings (Ref. ARAG General catalogue).
Avoid bends and constrictions before connections and on tubes.

Regarding connections, use tubes and fittings properly sized for the operating pressure of the system.

The tightening of hose tails should be made with special metal clamps ensuring perfect sealing even at high pressures.
The connection by means of threaded fittings should be done taking operating pressure into account.

CAUTION: For the implementation on already operating systems it is necessary to follow all safety rules described herein. 
System assembly and start-up must be carried out by expert personnel according to the safety rules so as to ensure the same 
safety level of the system the flowmeter is going to be installed in.

Tab. 4

Summary of Contents for Orion 2 46211A Series

Page 1: ...46211AXXXXX 46221AXXXXX ELECTROMAGNETIC FLOWMETER INSTALLATION USE AND MAINTENANCE...

Page 2: ...3 Preliminary setup for use 10 4 Use 10 5 Maintenance 11 5 1 Troubleshooting 11 5 2 Technical data 11 12 6 Guarantee terms 13 7 Disposal at the end of service 13 This manual is an integral part of th...

Page 3: ...h EN ISO 14982 standard Electromagnetic compatibility Forestry and farming machines harmonized with 2004 108 EC Directive The flowmeter must not be used to measure the passage of hydrocarbons flammabl...

Page 4: ...463 863 46211A00000 5 96 90 114 41 46211A10000 7 96 90 114 41 46211A20000 10 96 90 114 41 46211A30000 14 96 90 114 41 46211A40000 18 5 96 90 114 41 46221A40000 18 5 96 90 114 45 473 873 46221A50000 28...

Page 5: ...7 G 3 4 96 90 184 46211A21313 10 G 3 4 96 90 185 46211A23333 10 G 3 4 96 90 184 46211A31414 14 G 1 96 90 185 46211A33434 14 G 1 96 90 184 46211A41414 18 5 G 1 96 90 185 46211A43434 18 5 G 1 96 90 184...

Page 6: ...6 Dimensions mm DN H L T A T CODE DN T A H L 46211A3A5B5 14 T5 96 90 192 46211A4A5B5 18 5 T5 96 90 192 Fig 4 Tab 3...

Page 7: ...upwards OK OK Comply with the correct fluid inlet outlet direction as indicated by the arrow printed on the flowmeter body Fig 6 IN OUT IN OUT Use inlet and outlet pipes of the same diameter as the in...

Page 8: ...ve 2 4 Hydraulic connections For connection to the system use appropriate fittings Ref ARAG General catalogue Avoid bends and constrictions before connections and on tubes Regarding connections use tu...

Page 9: ...UNIT MAKE SURE THAT THE OPERATING PRESSURE IS SUITED FOR THAT SPECIFIC CONTROL UNIT FLOWMETERS WITH T5 FORK COUPLING CAN WITHSTAND A MAXIMUM PRESSURE OF 20 BAR ARAG is not liable for damages to the eq...

Page 10: ...t conductive fluids with a conductivity equal to 50 S cm Rif Tab 5 2 Chap 5 Do not aim pressurised water onto the equipment Respect the device s rated power requirement 12 Vdc If arc welding is requir...

Page 11: ...he flowmeter does not read any value No power supply Check the flowmeter wiring The value read by the flowmeter is not linear or stable Presence of turbulence or air in the circuit Check the circuit 5...

Page 12: ...22710 46211AG3333 0 3 6 0 08 1 6 40 580 0 3 4 G 3 4 4 6000 22710 46211A01313 0 5 10 0 13 2 6 20 290 0 3 4 G 3 4 5 6000 22710 46211A03333 0 5 10 0 13 2 6 40 580 0 3 4 G 3 4 5 6000 22710 46211A11313 1...

Page 13: ...lack of ordinary maintenance such as cleaning of filters nozzles etc anything that can be considered to be normal wear and tear 3 Repairing the apparatus will be carried out within time limits compati...

Page 14: ...14...

Page 15: ...ntemplati nella seguente Direttiva Europea 2004 108 CE e successive modificazioni Compatibilit Elettromagnetica Riferimenti alle Norme Applicate EN ISO 14982 Macchine agricole e forestali Compatibilit...

Page 16: ...RA Reggio Emilia ITALY Tel 39 0522 622011 Fax 39 0522 628944 www aragnet com info aragnet com Only use original ARAG accessories and spare parts to maintain safety conditions foreseen by the construct...

Reviews: