3
1
PRODUCT DESCRIPTION
The Orion 2 electromagnetic flowmeter is a device that enables measurement of the quantity of liquid passing through it.
Using a principle of electromagnetic measurement (there are no moving mechanical parts inside it), the flowmeter outputs a signal to the computer
proportional to the liquid flow that goes through it; Orion 2 displays the flowrate calculated according to the data received from the flowmeter and the
value of the flowmeter constant previously set.
1.1
Intended use
This device is designed to work on agricultural machinery for crop spraying applications.
The machine is designed and built in compliance with EN ISO 14982 standard (Electromagnetic compatibility - Forestry and
farming machines), harmonized with 2004/108/EC Directive.
The flowmeter must not be used to measure the passage of hydrocarbons, flammable, explosive or toxic liquids. The flowmeter is
not suitable for contact with liquids for human consumption. Use for sales transactions is not allowed.
2
INSTALLATION
Install the flowmeter
at least 20 cm
from the elements that could cause turbulence inside the tubes (valves, bends, constrictions, etc.).
The flowmeter can be installed in a horizontal or vertical position.
CAUTION:
For proper sealing of the flowmeter, use ARAG assembly kit ONLY (Ref. ARAG General catalogue - Accessories for series 463/473
modular valves).
ARAG is not liable for damage to the system, persons, animals or things caused by the use of material other than specified.
CONTINUES
Fig. 1