background image

Nr

ERROR MESSAGE

CAUSE

REMEDY

1

and

-

During treatment it is not
possible to distribute the
quantity of liquid per unit of
area set

- Reduce vehicle speed

-

Use nozzles capable of higher delivery
rates

- Increase the maximum working pressure

2

and

-

During treatment it is not
possible to distribute the
quantity of liquid per unit of
area set

- Increase vehicle speed

-

Use nozzles capable of lower delivery
rates

3

and

-

In AUTO mode the Bravo 300
is not receiving the flow-meter
signal

-

Check the connection between the

flow-meter and the Bravo 300

-

In AUTO mode the master

valve switch is on ON but the

control unit is not receiving any
liquid

- Check that the pump is operating

- Check that there is liquid in the tank

4

and

-

In AUTO mode the Bravo 300
is not receiving the speed
sensor signal

-

Check the connection between the speed
sensor and the Bravo 300

-

In AUTO mode the master

valve switch is on ON but the

machine is not moving

- Put the machine in motion

5

and                    and

-

In AUTO mode the Bravo 300
is not receiving the speed
sensor and flow-meter signals

-

Check the Bravo 300’s connections to

the speed sensor and flow-meter

-

In AUTO mode the master

valve switch is raised but the

machine is at a standstill

-

Put the machine in motion and start up

the pump

6

-

While regulating balancing-
valves, Bravo 300 surveys a
flow-rate, that is too low

-

Check connection between flow-meter
and Bravo 300

- Check flow-meter constant's  set-up

7

-

While setting wheel constant,

Bravo 300 didn't get the
correct pulses to calculate the
constant

-

Repeat wheel constant's automatic
set-up

8

-

After changing nozzle type,
balancing valves must be
adjusted

- Adjust balancing valves

9

-

Liquid in tank is below reserve
level

- Fill the tank

?

?

?

?

Operating errors

BRAVO30X monitors all distribution parameters constantly.
In case of a malfunction, the following error messages appear on the
display:

ErO

ErrOr

rEG

?

Summary of Contents for BRAVO30 Series

Page 1: ...Software No 54 GB 46730X 46730X 46730X 46730X 46730X SPRAY CONTROL USE AND MAINTENANCE USE AND MAINTENANCE USE AND MAINTENANCE USE AND MAINTENANCE USE AND MAINTENANCE...

Page 2: ...ing instructions must be observed Do not spray water on the equipment Do not use solvent or benzenes to clean the outer parts of the container Observe the foreseen power supply voltage 12 Vdc When arc...

Page 3: ...y calibration 12 Nozzle delivery rate 13 Settings preliminary to treatment 13 Field number 13 Resetting the field counters 14 Setting the amount of liquid placed in the tank 14 Filling up by means of...

Page 4: ...y Introduction BRAVO30X is a computer capable of controlling distribution of chemical products on sprayers equipped with valve control unit from 1 to 5 section valves It is composed of a control panel...

Page 5: ...the same time sends the data to the flow meter F and or pressure trasducer M so that the control panel A can handle the control unit BRAVO30X has a large backlit multifunction display on which the us...

Page 6: ...o the user programming menu Alternates display of the following data on the display Tank level Liquid distributed Battery voltage Alternates display of the following data on the display Flow rate Pres...

Page 7: ...Controls opening closing of sections Increase Decrease of quantity for distribution Increases the digit of the value for modification Decreases the digit of the value for modification Moves on to the...

Page 8: ...itches to the main menu page fig 5 Setting the contrast To modify the display contrast press the and keys to increase or and to decrease Fig 3 Display test Fig 4 Software release Treatment data displa...

Page 9: ...e wheel changes In this case the constant on the BRAVO30X has to be changed to allow it to measure the distance travelled correctly and thus make a correct calculation of the quantity of liquid delive...

Page 10: ...tor with the tank 50 full the test can be carried out with just water 2 Drive the tractor to the start of the straight track of known length and stop 3 If the length of the track is different from tha...

Page 11: ...e factor is 1 00 Press to confirm the value and exit or to exit without modifying Automatic density calibration The automatic density calibration procedure is carried out as follows 1 Fill the tank wi...

Page 12: ...ate to the nozzle in use To restore the ISO value simply press the key and confirm the values with the key See appendix for table 1 showing the relationship between pressure and flow rate for ISO nozz...

Page 13: ...rts the selection made and returns to the main menu screen Resetting the field counters The key can be pressed to reset the display of one or more of the counters relating to the field currently selec...

Page 14: ...are 2 588 litres inside the tank Once filling up is finished return to the main screen page by pressing key Selecting the nozzle The user will have selected the nozzle to be used for the treatment on...

Page 15: ...ete with calibrated return and if BRAVO30X has been programmed for operation with calibrated return during installation of the system at each nozzle change the flashing message rEG appears on the righ...

Page 16: ...nfirm the data and exit or press to exit without changing the data return is shown beside In the example if fig 19 this is 8 8 At this point the calibrated return has to be adjusted so that the two va...

Page 17: ...ment controlled in manual mode To perform a treatment in manual mode proceed as follows 1 Check that the symbol has illuminated in the centre of the display or press the so that it appears 2 Open the...

Page 18: ...be used to measure the distance between the field and the operator s home or to measure the length of a field N B the time worked count can be stopped or started by pressing the key When the count is...

Page 19: ...Total time 3 32 hhhh mm Counters printout If the printer code 467001 or the download software of data on the personal computer code 467002 is connected to BRAVO30X it will be possible to print the da...

Page 20: ...and the Bravo 300 In AUTO mode the master valve switch is on ON but the machine is not moving Put the machine in motion 5 and and In AUTO mode the Bravo 300 is not receiving the speed sensor and flow...

Page 21: ...t e n g a m f o o n e h t k s t e n g a m n e e w t e b e c n a t s i d e h t k c e h C r o s n e s d n a 5 t n a t s n o c t a n e v e e l b a t s n u s i y a l p s i D d e e p s s t e n g a m f o r...

Page 22: ...i Flow rate Litres min t min Gal min Speed Km h Km h Miles h Distribution Litres Ha t Ha Gal Acre Sect width metres metres feet Nozzle dist metres metres inches Flow constant pulse l pulse t pulse Gal...

Page 23: ...ns damage deriving from using unsuitable liquids failures caused by negligence tampering user incapability or repairs made by non authorized personnel installation and adjustment system references or...

Page 24: ...42048 RUBIERA Reggio Emilia ITALY Via Palladio 5 A Tel 0522 622011 Fax 0522 628944 Home page http www aragnet com E Mail info aragnet com D20033 GB m03 07 2005...

Reviews: