Concerning
Series 6000 and 7000 English Mark Dart Games
January 18, 1990
WARNING---DISCONNECT ELECTRICAL POWER BEFORE ATTEMPTING
SERVICE
We are recommending that the main fuse FS3 be upgraded from a 1.5 Amp
Slow Blow to a 2.0 Amp Slow Blow. Due to slight variances in components,
some games draw more current than others.
When these games are
connected to high line voltage, the current draw gets even higher, close to the
rating of the 1.5 Amp fuse. After a period of time, the fuse will blow, even
though the rating may not have been exceeded.
Since all of the components in the power supply are rated at a minimum of 2
Amps, no damage will occur as a result of this change. Do not exceed the 2.0
Amp rating, however. If the 2.0 Amp fuse blows, there is a definite problem
in the power supply, indicating it needs to be serviced by a qualified
technician.
If there are any problems regarding this or any other service problem, please
call ARACHNID, INC. at 800-435-83 19 or in Illinois at 8 15-654-02 12.
Arachnid, Inc.
John Farmer
Engineering Technician
6421 Material Ave
Rockford, 61111
8 15-654-02 12
800-435-83 19