54
Sequencer Output Parameters
Now that we have assigned a physical output channel
we can edit the output channel parameters.
Tap the green button marked
[26]
to go back into the
“
Seq Output Assign
”
page.
You will see the Output Channel is assigned to channel
26 and parameters for adjusting the Smooth Flite
physical output channel are now available.
Use Global Servo Speed—
tapping the check box will
allocate this output channel to use Global Servo
Speed to slow the servo or actuator down. The
servo speed is set on the
“
Sequencer Assign
”
Page.
Adjust OPEN Position—
Press and hold
[+]
or
[
-
]
to
move the gear to the
Open or Down
position and
then fine adjust the position.
Holding a button down will start adjusting in small
increments and then step to large increments.
Adjust Closed Position—
Press and hold
[+]
or
[
-
]
to move the gear to the
Closed or UP
position and
then fine adjust the position.
Hint: Holding a button down will begin adjusting in
small increments and then step
-
up to large
increments.
It is
IMPORTANT
that you set the
UP/CLOSED
and
DOWN/OPEN
position to match the physical
position of the gear and doors. Correct operation
of the sequencer relies on these being set correctly.
HINT: You can reverse a servo operation by simply swapping out OPEN and CLOSED values.
HINT: To step in large increments hold any adjust button down and the servo output will adjust in
small increments and then after a few steps will jump to large increments.