![AR 10051217 Operating And Service Manual Download Page 70](http://html1.mh-extra.com/html/ar/10051217/10051217_operating-and-service-manual_2962298070.webp)
Model 2000S1G2z8
46
Rev A
2.13.15
Forward Power Query
This command queries the internally detected forward power (values are corrected and linearized).
Query:
FPOW?
Response Format:
FPOW=<power><LF>
<power>:
The detected forward power (0-99999) in Watts (value is always five
characters, padded with spaces).
Example:
To query the forward power, send the following command:
FPOW?<LF>
Response:
FPOW=<space><space><space>54<LF>
(54 Watts of forward power)
2.13.16
Reverse Power Query
This command queries the internally detected reverse power (values are corrected and linearized).
Query:
RPOW?
Response Format:
RPOW=<power><LF>
<power>:
The detected reverse power (0-99999) in Watts (value is always five
characters, padded with spaces).
Example:
To query the reverse power, send the following command:
RPOW?<LF>
Response:
RPOW=<space><space><space><space>4<LF>
(4 Watts of forward power)
2.13.17
Operating Hours (RF ON) Query
This command queries the total hours spent with the RF enabled.
Query:
OH?
Response Format:
OH=<hours><LF>
<hours>:
The total hours with RF Enabled (0 to 100000), padded with spaces to always
be 6 digits wide.
Example:
To query the RF On operating hours, send the following command:
OH?<LF>
Response:
OH=<space><space><space><space>37<LF>
(The system has spent 37 Hours in an RF On state)
2.13.18
Operating Hours (Power ON) Query
This command queries hours spent in
Power ON
.
Query:
OHP?
Response Format:
OHP=x<LF>
<hours>:
The total hours with Power On (0 to 100000), padded with spaces to always be
6 digits wide.
Example:
To query the Power On operating hours, send the following command:
OHP?<LF>
Response:
OHP=<space><space><space>428<LF>
(The system has spent 428 Hours in a Power On state)
Summary of Contents for 10051217
Page 2: ......
Page 4: ......
Page 6: ......
Page 18: ...Model 2000S1G2z8 iv...
Page 22: ...Model 2000S1G2z8 4 Rev A...
Page 85: ...Model 2000S1G2z8 Rev A 61 Figure 4 2 Typical Response at 0 dBm Input...
Page 86: ...Model 2000S1G2z8 62 Rev A...
Page 88: ...Model 2000S1G2z8 64 Rev A...
Page 90: ......