![AR 10051217 Operating And Service Manual Download Page 68](http://html1.mh-extra.com/html/ar/10051217/10051217_operating-and-service-manual_2962298068.webp)
Model 2000S1G2z8
44
Rev A
2.13.13
Machine State Query
This command queries the RF gain, detector gain, ALC threshold, and ALC response time.
Query:
MSB?
Response Format:
RF<space>GAIN=<rf_gain>,DT<space>GAIN=<det_gain>,THRES=<alc_th
resh>,RESP=<resp><LF>
<rf_gain>:
The RF Gain setting (0-100%), padded with leading spaces to be 3 characters
<det_gain>:
The ALC Detector Gain (0-100%), padded with leading spaces to be 3
characters
<alc_thresh>:
The ALC Threshold setting (0-100%), padded with leading spaces to be 3
characters
<resp>:
1 character representing the ALC Response setting (1-7)
Example:
To query the machine state, send the following command:
MSB?<LF>
Response:
RF<space>GAIN=100,DT<space>GAIN=<space>50,THRES=75,RESP=1
<LF>
(RF gain is 100%, Detector Gain is 50%, ALC Threshold is 75%, and ALC
Response Time is set to 5mS)
2.13.14
Amplifier State Query
This command queries the state of the amplifier.
Query:
STATE?
Response Format:
STATE=<space><char1><char2><char3><char4><LF>
<char1> - <char4>:
ASCII character (0 to 9 or A to F) representing a hexadecimal character
Example:
To query the state of the amplifier, send the following command:
STATE?<LF>
Response:
STATE=<space>8301<LF>
(Remote Mode, Power On, RF OFF, and Manual Mode)
Summary of Contents for 10051217
Page 2: ......
Page 4: ......
Page 6: ......
Page 18: ...Model 2000S1G2z8 iv...
Page 22: ...Model 2000S1G2z8 4 Rev A...
Page 85: ...Model 2000S1G2z8 Rev A 61 Figure 4 2 Typical Response at 0 dBm Input...
Page 86: ...Model 2000S1G2z8 62 Rev A...
Page 88: ...Model 2000S1G2z8 64 Rev A...
Page 90: ......