Power
The Model 2000S1G2z8 is designed to operate using AC primary power of 200–240 Volts or 380-415
Alternating Current (VAC), 47–63 Hz, three phase, 15,000 watts maximum.
CAUTION:
Dangerous voltages are present in the Model 2000S1G2z8 whenever the
unit is plugged into an AC outlet. Always disconnect the unit from the main
power line when servicing it. Please note that neither the Keylock or Power
switch will completely shut off the unit’s AC power.
Low Voltage Model 10051217
: The Model 2000S1G2z8 is designed for a primary power input of 200–240
VAC, 47/63Hz, three phase Delta (4-wire) (Wye-compatible). A 63 amp or greater, common-trip circuit
breaker should be used to supply power to the 2000S1G2z8 low voltage model. Included with the low voltage
model is two 15 foot (4.7 meters), four-conductor harmonized line cords consisting of three phase wires (brown,
black and grey) and a protective GND conductor (green/yellow). The power cords are left open ended to allow
for facility power connection of user’s choice. Phase order is not critical for the 2000S1G2z8 amplifier.
High Voltage Model 10051218:
The Model 2000S1G2z8 is designed for a primary power input of 380–415
VAC, 47/63Hz, three phase Wye (5-wire). A 40 amp or greater, common-trip circuit breaker should be used to
supply power to the 2000S1G2z8 high voltage model. Included with the high voltage model is two 15 foot (4.7
meters), five-conductor harmonized line cords consisting of three phase wires (brown, black, grey), a neutral
conductor (blue) and a protective GND conductor (green/yellow). The power cords are left open-ended to allow
for facility power connection of user’s choice. Phase order is not critical for the 2000S1G2z8 amplifier.
Figure 1-1. 2000S1G2z8 AC Line Cord Installation
Summary of Contents for 10051217
Page 2: ......
Page 4: ......
Page 6: ......
Page 18: ...Model 2000S1G2z8 iv...
Page 22: ...Model 2000S1G2z8 4 Rev A...
Page 85: ...Model 2000S1G2z8 Rev A 61 Figure 4 2 Typical Response at 0 dBm Input...
Page 86: ...Model 2000S1G2z8 62 Rev A...
Page 88: ...Model 2000S1G2z8 64 Rev A...
Page 90: ......