![AR 1000S1G6C Operating And Service Manual Download Page 67](http://html1.mh-extra.com/html/ar/1000s1g6c/1000s1g6c_operating-and-service-manual_2962344067.webp)
Model 1000S1G6C
Rev A
43
2.11.15
Forward Power Query
This command queries the internally detected forward power (values are corrected and linearized).
Query:
FPOW?
Response Format:
FPOW=<power><LF>
<power>:
The detected forward power (0-99999) in Watts (value is always five
characters, padded with spaces).
Example:
To query the forward power, send the following command:
FPOW?<LF>
Response:
FPOW=<space><space><space>54<LF>
(54 Watts of forward power)
2.11.16
Reverse Power Query
This command queries the internally detected reverse power (values are corrected and linearized).
Query:
RPOW?
Response Format:
RPOW=<power><LF>
<power>:
The detected reverse power (0-99999) in Watts (value is always five
characters, padded with spaces).
Example:
To query the reverse power, send the following command:
RPOW?<LF>
Response:
RPOW=<space><space><space><space>4<LF>
(4 Watts of forward power)
2.11.17
Operating Hours (RF ON) Query
This command queries the total hours spent with the RF enabled.
Query:
OH?
Response Format:
OH=<hours><LF>
<hours>:
The total hours with RF Enabled (0 to 100000), padded with spaces to always
be 6 digits wide.
Example:
To query the RF On operating hours, send the following command:
OH?<LF>
Response:
OH=<space><space><space><space>37<LF>
(The system has spent 37 Hours in an RF On state)
2.11.18
Operating Hours (Power ON) Query
This command queries hours spent in
Power ON
.
Query:
OHP?
Response Format:
OHP=x<LF>
<hours>:
The total hours with Power On (0 to 100000), padded with spaces to always be
6 digits wide.
Example:
To query the Power On operating hours, send the following command:
OHP?<LF>
Response:
OHP=<space><space><space>428<LF>
(The system has spent 428 Hours in a Power On state)
Summary of Contents for 1000S1G6C
Page 2: ......
Page 4: ......
Page 6: ......
Page 18: ...Model 1000S1G6C ii...
Page 22: ...Model 1000S1G6C 4 Rev A...
Page 72: ...Model 1000S1G6C 48 Rev A...
Page 76: ...Model 1000S1G6C 52 Rev A...
Page 83: ...Model 1000S1G6C Rev A 59 Figure 4 2 Typical Response at 0 dBm Input...
Page 84: ...Model 1000S1G6C 60 Rev A...
Page 86: ......