![AR 1000S1G6C Operating And Service Manual Download Page 64](http://html1.mh-extra.com/html/ar/1000s1g6c/1000s1g6c_operating-and-service-manual_2962344064.webp)
Model 1000S1G6C
40
Rev A
2.11.10
ALC Response Setting Adjust
This command sets the ALC response setting. Adjusting this setting changes the ALC’s response time when
reacting to a detected increase in the RF Output that exceeds the ALC Threshold Level.
Syntax:
LEVEL:RESP<resp setting>
<resp setting>:
1
(fastest) to
7
(slowest), see table below
Query:
No (see the Machine State query command)
Example:
To set the ALC response time to its slowest value, send the following
command:
LEVEL:RESP7<LF>
Default Value:
1
Note:
Response Settings
Time (S)
1
5m
2
10m
3
30m
4
100m
5
1
6
3
7
3
2.11.11
Identity Query
This command queries the amplifier for its identity response.
Query:
*IDN?
Response Format:
AR-RF/MICROWAVE-INST,<model>,<firm rev><LF>
<model>:
The model designation of the amplifier.
<firm rev>:
The firmware revision of the control software.
Example:
To query the identity of the amplifier, send the following command:
*IDN?<LF>
Response:
AR-RF/MICROWAVE-INST,1000S1G6C,1.0<LF>
2.11.12
IO Board Firmware Revision Query
This command queries the firmware revision of the internal I/O Board.
Query:
*IOB?
Response Format:
INTERFACE_BOARD_SW_REV<firm rev><LF>
<firm rev>:
The firmware revision of the control software.
Example:
To query the firmware of the I/O board, send the following command:
*IOB?<LF>
Response:
INTERFACE_BOARD_SW_REV3.20<LF>
Summary of Contents for 1000S1G6C
Page 2: ......
Page 4: ......
Page 6: ......
Page 18: ...Model 1000S1G6C ii...
Page 22: ...Model 1000S1G6C 4 Rev A...
Page 72: ...Model 1000S1G6C 48 Rev A...
Page 76: ...Model 1000S1G6C 52 Rev A...
Page 83: ...Model 1000S1G6C Rev A 59 Figure 4 2 Typical Response at 0 dBm Input...
Page 84: ...Model 1000S1G6C 60 Rev A...
Page 86: ......