![AR 1000S1G6C Operating And Service Manual Download Page 53](http://html1.mh-extra.com/html/ar/1000s1g6c/1000s1g6c_operating-and-service-manual_2962344053.webp)
Model 1000S1G6C
Rev A
29
2.8.2.3
Connector J5
Notes:
Lines 3, 4:
Su3.3 Vdc via a 10kOhm pull-up resistor
Lines 1-4:
Guaranteed operation up to +30 Vdc
Lines 3, 4:
0 Vdc or +3.3 Vdc
TTL Inputs & OD Outputs:
Guaranteed operation up to +5 Vdc
TTL
= Digital
OD
= Open
Drain
Indicate NO ACTION STATE for TTL Inputs as HIGH (
H
) or LOW (
L
)
Indicate required TTL output state as HIGH (
H
) or LOW (
L
)
Indicate required OD output state as Floating (
F
) or Grounded (
G
)
Control
Lines
Select Function
input or output
Control States
Defined in section 4
Fault?
= Yes
General Description
Add fault description in Sec 6
Add non-fault description in section 7
TTL
In
TTL
Out
OD
Out
Pwr
OFF RF
OFF
Pwr ON
RF OFF
Pwr ON
RF ON
J5 – 1
J5 – 2
F
F
G
PS4 On/Off
J5 – 3
J5 – 4
J5 – 5
J5 – 6
J5 – 7
J5 – 8
J5 – 9
J5 – 10
H
Amp Fault, A7
J5 – 11
H
Amp Fault, A8
J5 – 12
J5 – 13
H
Amp Fault, A21
J5 – 14
H
Amp Fault, A22
J5 – 15
H
Amp Fault, A23
J5 – 16
H
Amp Fault, A24
J5 – 17
H
Amp Fault, A25
J5 – 18
H
Amp Fault, A26
J5 – 19
H
Amp Fault, A27
J5 – 20
H
Amp Fault, A28
J5 – 21
J5 – 22
H
H
Thermal Fault, A7
J5 – 23
H
H
Thermal Fault, A8
J5 – 24
J5 – 25
H
H
Thermal Fault, A21
J5 – 26
H
H
Thermal Fault, A22
J5 – 27
H
H
Thermal Fault, A23
J5 – 28
H
H
Thermal Fault, A24
J5 – 29
H
H
Thermal Fault, A25
J5 – 30
H
H
Thermal Fault, A26
J5 – 31
H
H
Thermal Fault, A27
J5 – 32
H
H
Thermal Fault, A28
J5 – 33
+3.3Vdc
J5 – 34
Ground
Summary of Contents for 1000S1G6C
Page 2: ......
Page 4: ......
Page 6: ......
Page 18: ...Model 1000S1G6C ii...
Page 22: ...Model 1000S1G6C 4 Rev A...
Page 72: ...Model 1000S1G6C 48 Rev A...
Page 76: ...Model 1000S1G6C 52 Rev A...
Page 83: ...Model 1000S1G6C Rev A 59 Figure 4 2 Typical Response at 0 dBm Input...
Page 84: ...Model 1000S1G6C 60 Rev A...
Page 86: ......