MAINTENANCE 

 

 

Page 9 

EN - English

 

ROUTINE CHECKS 

 
Regularly the user should perform a basic check to verify if the 
appliance  is  functioning  correctly,  on  the  basis  of  the 
following control points: 
1.

 

Check settings of electromechanical control panel. 

2.

 

Measure water hardness before/after appliance. 

3.

 

Check  drain  line  from  control  valve;  there  shouldn’t  be 
any water flow (unless appliance is in regeneration).  

4.

 

Check  drain  line  from  brine  cabinet  overflow;  there 
shouldn’t be any water flow. 

5.

 

Check appliance and surrounding area; there shouldn’t be 
any water leakages. 

 

BYPASSING THE APPLIANCE 

 
Occasionally  it  may  be  necessary  to  put  the  appliance 
hydraulically  in  bypass,  i.e.  to  isolate  it  from  the  water 
distribution system; f.e.: 

 

in case of an urgent technical problem; 

 

when  it  is  not  necessary to  supply treated  water  to  the 
house/application (refill swimming pool, irrigation,...). 

 
WITH 3-VALVE BYPASS SYSTEM (not included) 
 

  

Picture 6.a

 

SERVICE POSITION 

 = bypass valve is CLOSED 

 = inlet valve to appliance is OPEN 

 = outlet valve from appliance is OPEN 

 

  

Picture 6.b

 

BYPASS POSITION 

 = bypass valve is OPEN 

 = inlet valve to appliance is CLOSED 

 = outlet valve from appliance is CLOSED 

 

  

Picture 6.c

 

MAINTENANCE POSITION 

 = bypass valve is OPEN 

 = inlet valve to appliance is OPEN 

 = outlet valve from appliance is CLOSED 

 

WATER CONDITIONER SALT 

 

  

Picture 7

 

The appliance needs 'brine' for its periodic regenerations. This 
brine solution is made from water, that is automatically dosed 
in  the  brine  cabinet  by  the  brine  float  valve,  and  water 
conditioner  salt.  The  user  should  make  sure  that  the  brine 
cabinet is always kept full of water conditioner salt. Therefore 
he  should  periodically  check  the  salt  level  inside  the  brine 
cabinet and refill it if necessary. The salt lid can be removed 
completely to facilitate refilling.  
 
Ideally  the  level  of  water  conditioner  salt  inside  the  brine 
cabinet is kept between 1/3 and 2/3. A lower level of water 
conditioner  salt  can  cause  insufficient  brine  saturation, 
resulting in a loss of softening capacity. A higher level of water 
conditioner  salt  can  cause  salt  bridging  (hard  crust  or  salt 
bridges in the brine cabinet). When you suspect salt bridging: 

 

carefully  pound  on  the  outside  of  the  brine  cabinet  to 
break loose the salt bridges; 

 

using a broom (or like blunt tool) carefully push the salt to 
break it apart; 

 

pour warm water over the top of the salt to dissolve it. 

 

APPEARANCE 

 
To retain the appearance of the appliance, simply wipe it with 
a damp cloth or clean it with a mild soap solution; never use 
abrasive cleaners, ammonia or solvents. 
 

RESIN CLEANER 

 
Other contaminants (f.e. iron) present in the feed water can 
cause the resin bed to foul up, resulting in a loss of softening 
capacity. An approved resin cleaner can be used periodically 
to thoroughly clean the resin bed. 
 

SANITIZING THE APPLIANCE 

 
This  appliance  is  manufactured  from  premium  quality 
material and assembled in safe conditions to assure it is clean 
and sanitary. If installed and serviced correctly, this appliance 
will not infect or contaminate your water supply. However, as 
in any 'device' plumbed-in in your water distribution system, 
a  proliferation  of  bacteria  is  possible,  especially  in  case  of 
'stagnant water'. Therefore this appliance will automatically 
rinse the resin bed periodically. 
 
If  the  power  supply  to  the  appliance  is  disconnected  for  a 
longer  period  of  time,  we  recommend,  when  the  power 
supply  is  re-established,  to  manually  initiate  a  complete 
regeneration. 
 

Summary of Contents for Micro Chrono

Page 1: ...ono Rev2016 05 Micro Chrono EN Installation Operating Instructions WATER SOFTENER FR Instructions d Installation Emploi ADOUCISSEUR D EAU DE Installation Gebrauchsanleitung WASSERENTH RTER NL Installa...

Page 2: ...EN English Page 3 FR Fran ais Page 11 DE Deutsch Seite 19 NL Nederlands Pagina 27...

Page 3: ...____________________________ Model _______________________________________________________ Water hardness inlet _______________________________________ Water hardness outlet __________________________...

Page 4: ...nly be undertaken by a competent person aware of the local codes in force All plumbing and electrical connections must be done in accordance with local codes Before setting up the appliance make sure...

Page 5: ...environment where high ambient temperatures e g unvented boiler house or freezing temperatures can occur the appliance cannot be exposed to outdoor elements such as direct sunlight or atmospheric prec...

Page 6: ...e application to the outlet of the 3 valve bypass system DRAIN We recommend the use of a stand pipe with air trap To prevent backflow from the sewerage system into the appliance always install and use...

Page 7: ...r run for a few minutes until all air is purged fromthe installation and the resin bed is rinsed it is normal for the rinse water to show some discoloration close the tap 10 Check the appliance and al...

Page 8: ...Before starting the programming make sure that the control valve is in the service mode 1 TIME OF REGENERATION Turn the clock plate A until the desired time of regeneration appears in the time of rege...

Page 9: ...re he should periodically check the salt level inside the brine cabinet and refill it if necessary The salt lid can be removed completely to facilitate refilling Ideally the level of water conditioner...

Page 10: ...EN English Page 10...

Page 11: ...e ____________________________________________ Mod le ______________________________________________________ Duret d eau entr e _______________________________________ Duret d eau sortie _____________...

Page 12: ...nte au courant des codes locaux en vigueur Tous les raccordements hydrauliques et lectriques doivent tre r alis s en concordance aux codes locaux Avant d installer l appareil veuillez inspecter l appa...

Page 13: ...s un endroit o des temp ratures lev es Ex chaufferie non ventil e ou de gel peuvent se pr senter l appareil ne peut pas tre expos aux l ments ext rieurs comme la lumi re directe du soleil ou pr cipita...

Page 14: ...a plomberie maison la sortie du syst me de bypass 3 robinets GOUT Nous recommandons l usage d un tube rigide vertical avec une garde d air Afin de pr venir toute sorte de refoulement du r seau d gout...

Page 15: ...de l installation et pour rincer la r sine il est normal que l eau de rin age est l g rement d color e fermez le robinet 10 V rifiez que l appareil et tous les raccordements hydrauliques ne fuient pas...

Page 16: ...commande se trouve en mode service 1 HEURE DE R G N RATION Tournez le disque horaire A jusqu ce que l heure de r g n ration souhait e apparaisse dans la fen tre heure de r g n ration B 2 HEURE DU JOU...

Page 17: ...veau de sel dans le cabinet et le remplir si n cessaire Le couvercle de sel peut tre enlev compl tement pour faciliter le remplissage Id alement le niveau de sel dans le cabinet est maintenu entre 1 3...

Page 18: ...FR Fran ais Page 18...

Page 19: ...____________________ Model _______________________________________________________ Wasserh rte Einlass ________________________________________ Wasserh rte Auslass ____________________________________...

Page 20: ...en Person erfolgen die zus tzlich ber alle notwendigen gesetzlichen Regelungen Kenntnis hat Alle Sanit r und elektrischen Anschl sse m ssen in bereinstimmung mit den rtlichen Vorschriften durchgef hrt...

Page 21: ...ie Anlage nicht in einer R umlichkeit wo zu hohe oder zu niedrige Umgebungstemperaturen herrschen die Anlage ist nicht f r den Au enbereich geeignet installieren Sie die Anlage nicht in direkter N he...

Page 22: ...ABFLUSS Wir empfehlen die Verwendung eines Standrohrs mit Geruchsverschluss Um einen R ckfluss von Abwasser in der Anlage zu verhindern installieren und verwenden Sie immer den mitgelieferten Ablaufa...

Page 23: ...he der Anlage befindet und lassen Sie das Wasser einige Minuten laufen um die Anlage zu entl ften und das Harz zu sp len es ist normal dass das Sp lwasser leicht verf rbt ist schlie en Sie den Wasser...

Page 24: ...s befindet 1 REGENERATIONSZEITPUNKT Drehen Sie die Uhrscheibe A bis den gew nschten Regenerationszeitpunkt im Fenster B erscheint 2 UHRZEIT Drehen Sie den Schaltuhrknopf H gegen den Uhrzeigersinn bis...

Page 25: ...Salzbeh lter kontrollieren und falls erforderlich nachf llen Das Salzdeckel kann vollst ndig entfernt werden um das nachf llen zu erleichtern Die optimale F llmenge des Salzes liegt zwischen 1 3 und 2...

Page 26: ...DE Deutsch Seite 26...

Page 27: ..._________________________________________ Model _______________________________________________________ Waterhardheid ingang _____________________________________ Waterhardheid uitgang _______________...

Page 28: ...kale regelgeving Alle hydraulische en elektrische aansluitingen dienen uitgevoerd te worden in overeenstemming met de lokale regelgeving Alvorens het toestel te installeren gelieve het toestel eerst t...

Page 29: ...n bijv ongeventileerde boilerruimte of vriestemperaturen kunnen voorkomen het toestel mag niet worden blootgesteld aan de buitenomgeving zoals direct zonlicht of neerslag installeer het toestel niet t...

Page 30: ...OOL Wij raden het gebruik aan van een standpijp met waterslot Om terugstroming vanuit het rioolstelsel in het toestel te vermijden installeer en gebruik steeds de meegeleverde riooladaptor met luchtsp...

Page 31: ...laat het water gedurende enkele minuten lopen tot alle lucht uit de installatie verdwenen is en het harsbed gespoeld is het is normaal dat het spoelwater enige verkleuring vertoont sluit de kraan 10 C...

Page 32: ...an te vangen met de programmering zorg ervoor dat de besturingsklep zich in de bedrijfsmodus bevindt 1 REGENERATIETIJDSTIP Draai de klokplaat A tot het gewenste regeneratietijdstip in het raam van het...

Page 33: ...zoutniveau regelmatig nagekeken en indien nodig bijgevuld te worden Het zoutdeksel kan volledig weggenomen worden om het vullen te vergemakkelijken Idealiter wordt het zoutniveau in het pekelkabinet t...

Page 34: ...2016 erie water treatment PP MicroChrono Rev2016 04 Micro 1 a 1 b 2 a 2 b 3...

Page 35: ...2016 erie water treatment PP MicroChrono Rev2016 04 Micro 4 5 6 a 6 b...

Page 36: ...2016 erie water treatment PP MicroChrono Rev2016 04 Micro 6 c 7 a 7 b...

Page 37: ......

Page 38: ...Manufactured Assembled by erie water treatment a division of Aquion Inc www eriewatertreatment com...

Reviews: