Aquion Micro Chrono Installation & Operating Instructions Manual Download Page 7

COMMISSIONING 

 

 

Page 7 

EN - English

 

ELECTRICAL 

 

  

Picture 3

 

1.

 

Plug the transformers output lead into the socket on the 
appliances  power  cord;  secure  it  by  means  of  the 
TwistLock clamp. 

2.

 

Plug the transformer into an electrical outlet. 

 

BRINE CABINET 

 
3.

 

Add water conditioner salt to the brine cabinet. 

 

PRESSURIZING

 

 
4.

 

Make sure the bypass system is in 'bypass' position. 

5.

 

Make  sure  the  electromechanical  controller  of  the 
appliance is in service mode.  

6.

 

Open the mains water supply. 

7.

 

Open  a  cold  treated  water  faucet  nearby  the  appliance 
and  let  the  water  run  for  a  few  minutes  until  all  air  is 
purged  and  all  foreign  material  that  may  have  resulted 
from the installation is washed out; close the tap. 

8.

 

Gently pressurize the appliance, by putting it into service: 

 

factory bypass: 
1.

 

open the 'outlet' valve; 

2.

 

slowly open the 'inlet' valve.  

 

3-valve bypass: 
1.

 

close the 'bypass' valve; 

2.

 

open the 'outlet' valve; 

3.

 

slowly open the 'inlet' valve. 

9.

 

After  2-3  minutes,  open  a  cold  treated  water  faucet 
nearby  the  appliance  and  let  the  water  run  for  a  few 
minutes until all air is purged from the installation and the 
resin bed is rinsed (it is normal for the rinse water to show 
some discoloration!); close the tap. 

10.

 

Check  the  appliance  and  all  hydraulic  connections  for 
leaks. 

 

 

After  the  first  regenerations  of  the  appliance,  some 

slight discoloration of the treated water might occur. This is 
totally harmless and will disappear rapidly! 
 

ELECTROMECHANICAL CONTROL PANEL 

 
11.

 

Program the electromechanical controller. 

 

ADJUSTMENT RESIDUAL HARDNESS 

 

 

In  practice  the  residual  hardness  is  influenced  by  the 

inlet  pressure,  flow  rate  and  hardness  of  the  incoming 
untreated  water.  When  adjusting  the  residual  hardness, 
make  sure  these  conditions  are  similar  to  the  actual 
operating conditions. 
 

  

Picture 4

 

12.

 

Adjust the residual hardness of the water that leaves the 
softener,  by  means  of  the  adjusting  screw  (

), 

incorporated in the control valve: 

 

to raise the residual hardness: turn the screw counter 
clockwise. 

 

to  reduce  the  residual  hardness:  turn  the  screw 
clockwise. 

13.

 

Measure  the  residual  water  hardness  with  a  water 
hardness test kit; readjust if necessary.  

 

PERFORM REGENERATION 

 
14.

 

Manually  initiate  a  regeneration  (refer  to  section 
'ELECTROMECHANICAL CONTROL PANEL'). 

Summary of Contents for Micro Chrono

Page 1: ...ono Rev2016 05 Micro Chrono EN Installation Operating Instructions WATER SOFTENER FR Instructions d Installation Emploi ADOUCISSEUR D EAU DE Installation Gebrauchsanleitung WASSERENTH RTER NL Installa...

Page 2: ...EN English Page 3 FR Fran ais Page 11 DE Deutsch Seite 19 NL Nederlands Pagina 27...

Page 3: ...____________________________ Model _______________________________________________________ Water hardness inlet _______________________________________ Water hardness outlet __________________________...

Page 4: ...nly be undertaken by a competent person aware of the local codes in force All plumbing and electrical connections must be done in accordance with local codes Before setting up the appliance make sure...

Page 5: ...environment where high ambient temperatures e g unvented boiler house or freezing temperatures can occur the appliance cannot be exposed to outdoor elements such as direct sunlight or atmospheric prec...

Page 6: ...e application to the outlet of the 3 valve bypass system DRAIN We recommend the use of a stand pipe with air trap To prevent backflow from the sewerage system into the appliance always install and use...

Page 7: ...r run for a few minutes until all air is purged fromthe installation and the resin bed is rinsed it is normal for the rinse water to show some discoloration close the tap 10 Check the appliance and al...

Page 8: ...Before starting the programming make sure that the control valve is in the service mode 1 TIME OF REGENERATION Turn the clock plate A until the desired time of regeneration appears in the time of rege...

Page 9: ...re he should periodically check the salt level inside the brine cabinet and refill it if necessary The salt lid can be removed completely to facilitate refilling Ideally the level of water conditioner...

Page 10: ...EN English Page 10...

Page 11: ...e ____________________________________________ Mod le ______________________________________________________ Duret d eau entr e _______________________________________ Duret d eau sortie _____________...

Page 12: ...nte au courant des codes locaux en vigueur Tous les raccordements hydrauliques et lectriques doivent tre r alis s en concordance aux codes locaux Avant d installer l appareil veuillez inspecter l appa...

Page 13: ...s un endroit o des temp ratures lev es Ex chaufferie non ventil e ou de gel peuvent se pr senter l appareil ne peut pas tre expos aux l ments ext rieurs comme la lumi re directe du soleil ou pr cipita...

Page 14: ...a plomberie maison la sortie du syst me de bypass 3 robinets GOUT Nous recommandons l usage d un tube rigide vertical avec une garde d air Afin de pr venir toute sorte de refoulement du r seau d gout...

Page 15: ...de l installation et pour rincer la r sine il est normal que l eau de rin age est l g rement d color e fermez le robinet 10 V rifiez que l appareil et tous les raccordements hydrauliques ne fuient pas...

Page 16: ...commande se trouve en mode service 1 HEURE DE R G N RATION Tournez le disque horaire A jusqu ce que l heure de r g n ration souhait e apparaisse dans la fen tre heure de r g n ration B 2 HEURE DU JOU...

Page 17: ...veau de sel dans le cabinet et le remplir si n cessaire Le couvercle de sel peut tre enlev compl tement pour faciliter le remplissage Id alement le niveau de sel dans le cabinet est maintenu entre 1 3...

Page 18: ...FR Fran ais Page 18...

Page 19: ...____________________ Model _______________________________________________________ Wasserh rte Einlass ________________________________________ Wasserh rte Auslass ____________________________________...

Page 20: ...en Person erfolgen die zus tzlich ber alle notwendigen gesetzlichen Regelungen Kenntnis hat Alle Sanit r und elektrischen Anschl sse m ssen in bereinstimmung mit den rtlichen Vorschriften durchgef hrt...

Page 21: ...ie Anlage nicht in einer R umlichkeit wo zu hohe oder zu niedrige Umgebungstemperaturen herrschen die Anlage ist nicht f r den Au enbereich geeignet installieren Sie die Anlage nicht in direkter N he...

Page 22: ...ABFLUSS Wir empfehlen die Verwendung eines Standrohrs mit Geruchsverschluss Um einen R ckfluss von Abwasser in der Anlage zu verhindern installieren und verwenden Sie immer den mitgelieferten Ablaufa...

Page 23: ...he der Anlage befindet und lassen Sie das Wasser einige Minuten laufen um die Anlage zu entl ften und das Harz zu sp len es ist normal dass das Sp lwasser leicht verf rbt ist schlie en Sie den Wasser...

Page 24: ...s befindet 1 REGENERATIONSZEITPUNKT Drehen Sie die Uhrscheibe A bis den gew nschten Regenerationszeitpunkt im Fenster B erscheint 2 UHRZEIT Drehen Sie den Schaltuhrknopf H gegen den Uhrzeigersinn bis...

Page 25: ...Salzbeh lter kontrollieren und falls erforderlich nachf llen Das Salzdeckel kann vollst ndig entfernt werden um das nachf llen zu erleichtern Die optimale F llmenge des Salzes liegt zwischen 1 3 und 2...

Page 26: ...DE Deutsch Seite 26...

Page 27: ..._________________________________________ Model _______________________________________________________ Waterhardheid ingang _____________________________________ Waterhardheid uitgang _______________...

Page 28: ...kale regelgeving Alle hydraulische en elektrische aansluitingen dienen uitgevoerd te worden in overeenstemming met de lokale regelgeving Alvorens het toestel te installeren gelieve het toestel eerst t...

Page 29: ...n bijv ongeventileerde boilerruimte of vriestemperaturen kunnen voorkomen het toestel mag niet worden blootgesteld aan de buitenomgeving zoals direct zonlicht of neerslag installeer het toestel niet t...

Page 30: ...OOL Wij raden het gebruik aan van een standpijp met waterslot Om terugstroming vanuit het rioolstelsel in het toestel te vermijden installeer en gebruik steeds de meegeleverde riooladaptor met luchtsp...

Page 31: ...laat het water gedurende enkele minuten lopen tot alle lucht uit de installatie verdwenen is en het harsbed gespoeld is het is normaal dat het spoelwater enige verkleuring vertoont sluit de kraan 10 C...

Page 32: ...an te vangen met de programmering zorg ervoor dat de besturingsklep zich in de bedrijfsmodus bevindt 1 REGENERATIETIJDSTIP Draai de klokplaat A tot het gewenste regeneratietijdstip in het raam van het...

Page 33: ...zoutniveau regelmatig nagekeken en indien nodig bijgevuld te worden Het zoutdeksel kan volledig weggenomen worden om het vullen te vergemakkelijken Idealiter wordt het zoutniveau in het pekelkabinet t...

Page 34: ...2016 erie water treatment PP MicroChrono Rev2016 04 Micro 1 a 1 b 2 a 2 b 3...

Page 35: ...2016 erie water treatment PP MicroChrono Rev2016 04 Micro 4 5 6 a 6 b...

Page 36: ...2016 erie water treatment PP MicroChrono Rev2016 04 Micro 6 c 7 a 7 b...

Page 37: ......

Page 38: ...Manufactured Assembled by erie water treatment a division of Aquion Inc www eriewatertreatment com...

Reviews: