POH
AQUILA AT01-200C
SECTION 3
EMERGENCY PROCEDURES
Document Nr.:
Issue:
Supersedes Issue:
Date:
Page:
FM-AT01-1010-106
A.01
--- (first issue)
02.03.2020
3 - 12
3.5.2 Engine Fire In-flight
1.
Throttle
WIDE OPEN
2.
Fuel selector valve
OFF
3.
Cabin heat
PUSHED (OFF)
4.
Canopy slide-window
OPEN
5.
Perform a precautionary landing without engine power as described in Section 3.4.2
3.5.3 Electrical Fire with Smoke on the Ground
1.
ALT1 / BAT
switch
OFF
2.
ALT2 / BAT2
switch
OFF
If engine is running:
3.
Throttle
IDLE
4.
Fuel selector valve
OFF
5.
Ignition switch
OFF
6.
Canopy
OPEN
7.
Fire extinguisher (if installed)
USE as required
3.5.4 Electrical Fire with Smoke in Flight
1.
ALT1 / BAT
switch
OFF
2.
ALT2
switch
OFF (
BAT2
still ON)
3.
Avionics
switch
OFF
4. All switches (except Ignition)
OFF
5. Cabin ventilation and canopy slide-window
OPEN
6. Fire extinguisher (if installed)
Use only if smoke persists
7. Land immediately
Refer to Section 3.4 Forced Landings
After landing and aircraft comes to a halt:
8. Engine
Shut down
9. Canopy
OPEN
10. After engine stops
Evacuate aircraft
CAUTION
When a large amount of smoke is present or the fire extinguisher has been used, ventilate the
cabin by unlocking the canopy latch. If possible, the fire extinguisher should be secured after
use.
WARNING
Turning the ALT1 / BAT and ALT2 switches OFF turns off all electrical and electronic
equipment, including the flaps