3.10.5 Low Voltage Indication
A)
On the ground (voltmeter values YELLOW or RED)
1.
Engine speed
Increase RPM until value turns
GREEN (RPM should be below
1350)
2.
All non-essential equipment
OFF, until value turns GREEN.
3.
If the value remains YELLOW or RED
Do not fly before problem is
eliminated.
B)
In flight (voltmeter values YELLOW or RED)
1.
All non-essential equipment
OFF, until value turns from YELLOW to
GREEN or from RED to YELLOW
2.
If the value remains YELLOW or RED
CHECK ammeter for defective
alternator(s)
for
ALT1 + ALT2
acc.section 3.10.2
for
ALT1
acc. section 3.10.3
for
ALT2
acc. section 3.10.4
C)
During approach and landing (voltmeter value YELLOW or RED)
1.
After landing
Proceed in accordance with section
3.10.5 A)
WARNING
If, at any point, the voltmeter value turns RED, land at the nearest airfield and solve the
problem before continuing flight.