Using the Included Mounting Bracket
Each sentia™dose Primary Control Unit and/or Secondary Unit includes a mounting bracket for optionally securing
the Unit(s) as desired. The included Mounting Plate can be secured with the included Screws or the included
Adhesive Strips. The Mounting Plates for any number of Units in sequence interlock to neighboring Units. Mounting
Plates should be secured in sequence to the mounting location. Once secured, the entire group of Units can be
attached to the line of Mounting Plates.
Setting Up Doser Pump Heads and Tubing
Placement of the sentia™dose Primary Control Unit and/or connected Secondary Unit(s) is unique to each user’s
circumstance. In general, the system should be set up for ease of access to any supplements being dosed while
being within a comfortable proximity to the aquarium or sump being dosed. Any length of tubing distance is
generally feasible given proper calibration of the solution being dosed.
Additionally, the Pump Head can be adjusted to 8 different positions by turning the Pump Head gently clockwise
to unlock its position. The Pump Head can then be turned to the various other positions and then locked back
into place by lowering it into the chosen position and turning it counter clockwise. This allows the Unit(s) to be
positioned horizontally, vertically, diagonally, etc. to facilitate the best position for each user’s application. All
sentia™dose Primary Control Units and Secondary Units come with the Pump Head already assembled.
Connect a Tubing Connector to each end of the Pump Head tubing. When facing the Pump Head directly the flow
through the doser is in through the Right Tube and out through the Left Tube. Approximately 1 meter of Tubing is
included with each Primary Control Unit and Secondary Unit. Install the appropriate length of tubing required from
the supplement reservoir or bottle to the inflow side (Right Tube when facing Unit) of a unit making certain that
the length of tubing extends all the way to the bottom of the resevoir easily. Install the appropriate length of tubing
required from the Primary Control Unit and/or connected Secondary Unit outflow side (Left Tube when facing Unit)
to the aquarium or sump being dosed. Make certain the line is secure and that the output end of the line is above
the water line. Additional tubing is available in 3 meter segments as an accessory from your dealer.
Colored Rings for Pump Heads are intended to coordinate with the Colored Clip for each tube run to avoid confusion
when using multiple dosers. The Pump Head Colored Ring can be removed by lightly pulling up at the indention
where the Colored Ring meets the Pump Head. Simply replace the Colored Ring as desired and press down on the
Colored Ring to secure it to the Pump Head. A corresponding Colored Clip can then be installed on the end of the
output line at the aquarium or sump being dosed.