9 - 26
IsACQ455C-0 (ENG) Rev. 261108-0
Via dell’Industria, 20 - 42025 Cavriago (RE) Italy Tel.: +39 0522 494403
Fax: +39 0522 494410 http:\\www.aquatronica.com E-mail: [email protected]
Manual controls menu
(Fig. 7)
(Fig. 8)
(Fig. 9)
Dimmer Pompe
01: Iodio
02: Calcio
03: Plancton
Single control
P2
30%
P3
0%
P1
100%
(Fig. 10)
P4
----
Manual controls (Single control)
Used to keep the power of each single pump at the
required value. From a minimum of 30% to a maxi-
mum of 100% (Example in Fig.8). This symbol “----”
points out that the pump is controlled according to the
set program.
Proceed as follows to select this function:
Main screen page
Main menu
Dimmer Pumps
Manual controls
Single control.
•
Select the output required using the right/left ar-
row keys
and use the up/down arrow keys
to
change its status; upon completion, press
“Enter”
.
Manual controls (All at maximum) (Fig. 9)
Used to set all the pumps at their maximum power
(100%).
Proceed as follows to use this function:
Main screen page
Main menu
Dimmer pumps
Manual controls
All at maximum.
•
Select the
“All at maximum”
function using the
up/down arrow keys
and press
“Enter”
.
Manual controls (All off) (Fig. 10)
Used to switch all the pumps off simultaneously.
Proceed as follow to use this function:
Main screen page
Main menu
Dimmer pumps
Manual controls
All off.
•
Select the “
All off
” function using the up/down ar-
row keys
and press
“Enter”
.
Manual controls (All at minimum) (Fig. 11)
Used to set all the pumps at their minimum power
(30%).
Proceed as follow to use this function:
Main screen page
Main menu
Dimmer pumps
Manual controls
All at minimum.
•
Select the “
All at minimum
” function using the up/
down arrow keys
and press
“Enter”
.
Reset All (Fig. 12)
Used to set the pumps back at the power foreseen by
the program currently in use (----).
Proceed as follow to use this function:
Main screen page
Main menu
Dimmer pumps
Manual controls
Reset All.
•
Select the “
Reset
” function using the up/down arrow
keys
and press
“Enter”
.
Dimmer pumps 1
About
Programs
Change name
Manual controls
All at maximum
P2
100%
P3
100%
P1
100%
P4
100%
All off
P2
0%
P3
0%
P1
0%
P4
0%
All at minimum
P2
30%
P3
30%
P1
30%
P4
30%
(Fig. 11)
Reset All
P2
----
P3
----
P1
----
P4
----
(Fig. 12)