background image

Function : Form : Fashion

Aquaticausa.com  
Aquaticabath.ca
E:
 [email protected] 

Multiplex Duo

 

Shower Control

Installation & Care Manual

INTERNATIONAL

Function : Form : Fashion

Function : Form : Fashion

Summary of Contents for Multiplex Duo

Page 1: ...Function Form Fashion Aquaticausa com Aquaticabath ca E info aquaticabath com Multiplex Duo Shower Control Installation Care Manual INTERNATIONAL Function Form Fashion Function Form Fashion ...

Page 2: ...is 70mm 2 3 4 35mm 1 4 depth is required if the rear of the bracket is cut down Cables mounted on surfaces must be protected by a suit able approved conduit This applies even in a loft where there may be a risk of damage by vermin Cables that are chased into walls must also be protected by a conduit or sheathing to allow removal for service and maintenance The power lead must not be replaced by an...

Page 3: ...E CONTROL CONTROL FIXINGS CONTROL FIXING BRACKETS DUO FLOW OUTLET CONTROL ADAPTOR RING SETS BACK PLATES FOAM GASKETS DUO TEMPERATURE CONTROL DUO FLOW OUTLET CONTROL INLET OUTLET CONNECTORS BACK UP BATTERY SUPPLY PROCESSOR FIXINGS PROCESSOR DUAL OUTLET SHOWER MDUOSH BATH MDUOBATH TOOLS REQUIRED PENCIL CROSSHEAD SCREWDRIVER 8MM DRILL BIT ADJUSTABLE SPANNER DRILL ...

Page 4: ...nding on Dynamic water pressure of supply system to the processor All products marked LP Low pressure and MP Medium pressure are also suitable for HP High pressure systems Please note This product must work from a minimum water pressure of 05 bar and above Water pressure recommended MP minimum 0 5 bar HP1 minimum 1 bar HP2 minimum 2 bar HP3 minimum 3 bar HP4 minimum 4 bar Aquaticausa com Aquaticab...

Page 5: ...r cable must be secured and chased into the wall this must not be left exposed as in the event of a possible leak the cable will be protected Please make sure the cable is installed by a qualified electrician and has certificates to back this up Important The Processor must have an access panel Note The controller can be fitted anywhere in the showering area Cable length 6m max Bath filler Handset...

Page 6: ...UO CEILING MOUNTED INSTALLATION SCENARIO handshower and fixed overhead shower configuration Handset fixed head outlets Cable length 6m max Note The controller can be fitted anywhere in the showering area MULTIPLEX DUO BATH SHOWER CEILING MOUNTED INSTALLATION SCENARIO handshower and bath filler Cable length 6m max Extension cables for the Bath filler control are available Bath Filler Handset oiutle...

Page 7: ...nance Note If a double trim plate is used the control fixing brackets must be positioned so that the openings at the back are horizontal as shown Attach the control fixing brackets using the screws supplied Brackets attached from behind Function Form Fashion 1 Multiplex Duo Shower ControlShower Control INSTALLATION SEQUENCE Shower Control Option To make the installation easier we recommend that th...

Page 8: ...h the wall Carefully cut down the bracket collars as marked Note Feeding a string or wire through the brackets and conduit will make it easier to pull the cables through to the processor Without optional trim plate String or wire Position the adaptor rings inside the back plate foam gaskets and fix through the adaptor ring holes into the bracket collars using the 15mm screws supplied Back plate Ad...

Page 9: ...d turn clockwise to lock in position Push fit the front control wheels onto the controls Now follow step 16 on page 11 Carefully pull the front control wheel off the controls taking care not to mix them up Feed the foam seals onto the data cables and onto the control bodies Feed the control data cables through the brackets Note The Multiplex Duo Temperature control should be in the top position an...

Page 10: ...om the control brackets by pulling off the front control wheel turning the control bodies anti clockwise and liffting out To refit position the control bodies in the slots and turn clockwise 12 13 14 15 Bath control option O ring Prepare the bath rim to take the control fixing brackets 35mm diameter holes are required to fit the brackets Feed the control data cables through the holes then insert t...

Page 11: ...essor 16 15VB attery WLAN ValveC ontrollerD ual Wheel Inside Processor Dual outlet Connector block Fixing Holes Cover retaining holes Note Outlet 1 is the default outlet when turned on water will flow through this outlet first If a bath filler option is required it must be connected to outlet 1 Battery compartment Power supply Hot Cold Inlets Outlets ...

Page 12: ... inlet connectors into the inlet valves one long and one short connector Note If required the nut ends of the inlet connectors and outlet connectors can be cut off and compression fittings can be used to attach the pipework 17 18 19 20 Connecting the processor Fix the processor in position using the fixings supplied Remove the inlet connectors retaining bolt 15VB attery WLAN ValveC ontrollerD ual ...

Page 13: ...tors into the outlet valves Note Outlet 1 is the default outlet when turned on water will flow through this outlet first If a bath filler option is required it must be connected to outlet 1 21 22 23 24 Connecting the processor Important Flush through the pipework before connection Attach the 15mm hot and cold water supply connections Remove the outlet connectors retaining bolt 15VB attery WLAN Val...

Page 14: ...at Note Make sure that the pipework is perpendicular to the processor so that there is no strain on the fittings use pipe clips as required Run a pipe from the mixed water outlet on the processor through the wall to the proposed position of the shower hose outlet etc Connect the data cable from the temperature control to the Controller connection in the processor Re insert the outlet connectors re...

Page 15: ...w outlet control to the Dual Wheel connection in the processor 28 29 Connect flow outlet control data cable Connect the battery cable to the Battery for battery back up connection and place the battery in the compartment 15V Battery WLAN Valve Controller Dual Wheel Display WLAN ValveC ontrollerD ual Wheel Display 15V Battery WLAN Valve Controller Dual Wheel Display 15VB attery ...

Page 16: ...ass and will invalidate your guarantee WARRANTY Aquatica Multiplex series digital shower and bath controllers carry a 5 year warranty that covers all manufacturing defects This warranty does not cover damage caused during fitting damage resulting from incorrect installation or damage caused by misuse or inappropriate cleaning Please do not disassemble the processor unit as this will invalidate you...

Page 17: ...Function Form Fashion MultiplexTrio Shower Control Function Form Fashion Ø8 x 55 Ø8 x 55 this side up this side up 235mm 9 2inch Note Diagram is to scale Ensure when printing that image size is at 100 ...

Page 18: ...Aquaticausa com Aquaticabath ca E info aquaticabath com Multiplex Duo Shower ControlShower Control ...

Page 19: ...Function Form Fashion Function Form Fashion ...

Page 20: ...Aquaticausa com Aquaticabath ca E info aquaticabath com Function Form Fashion Function Form Fashion ...

Reviews: