General Installation
Water Pressure
Minimum 25 PSI
Electrical Supply
Uninterrupted AC 115V
Existing Plumbing
Free of any deposits or build-ups inside pipes.
Unit Location
Locate close to drain and connect according to plumbing codes
Bypass Valves
Always provide for bypass valve if unit is not equipped with one.
Plumbing
Softener and or other water treatment equipment should be
installed to local plumbing codes
CAUTION
Do not exceed 120 psi water pressure.
Do not exceed 110°F water temperature.
Do not subject unit to freezing
conditions.
Figure 5. Standard Installation
Figure 6. Municipal Supply Installation
Figure 7. Split Stream Installation
Media Installation
(When Necessary)
Remove the valve from the mineral tank.
Temporarily plug the open end of the central pipe in the tank to insure that no media or gravel falls down into the distribution.
Fill mineral tank one quarter full of water to protect distribution during gravel installation.
Slowly and carefully add the gravel support bed and the filtration media leveling each layer as it is placed into the tank.
Unplug the riser tube, carefully position the valve over it and turn the valve into the threads in the fiberglass tank, tightening
securely into tank.
Note:
Ensure that the internal O-ring in the valve fits securely over the riser tube. Silicone grease (#13691) or other food grade
lubricant may be applied to the O-ring to ease installation of the riser tube. DO NOT use petroleum based lubricants as
they will cause swelling of O-ring seals.
Pressure tank
Air injector
Birm filter
Well water from
pump
Iron free water
Air vent
Pressure switch to
pump
Pressure tank
Air injector
Birm filter
Municiple water
supply
Iron free water
Air vent
NC Solenoid valve
Pressure switch
Secondary Pressure tank
Air injector
Birm Filter
Well water from
pump
Iron free water
Air vent
Pressure switch to
solenoid
Primary Pressure tank
NC Solenoid valve
Pressure switch to well
pump
Secondary raw
water line