14
AQUASURE
HARMONY SERIES
STEP 2.
System Startup
1.
When power is supplied to the control, the screen will display the time of day, gallons
remaining and the regeneration mode. Press and hold the “Cycle” button for 5 seconds
until you see the words “
goto bW
” and then release the “Cycle” button. The backwash
(
bW
) will be underway.
2.
Once the valve is in the backwash (
bW
) cycle, you will see the 15-minute (015) countdown
next to “
bW
”. Open the inlet on the bypass valve slowly and allow water to enter the unit. If
you hear any large “knocking” sounds, turn the red inlet valve partially closed (not all the
way) as the water is being fed too quickly and should be slowed. This process will begin to
purge air from the resin tank and fill the resin tank with water, allowing the air to escape
to the drain line. The water to the drain line will eventually start to run clear after 3-4
minutes.
3.
After the backwash you will see the system move into the brine draw (
bd
). The brine draw
is 60 minutes total and will normally draw out the saltwater within 20-30 minutes leaving
the rest of the time for the saltwater to bond with the resin. After the BD the rapid rinse
(
rr
) will start for a duration of 10 minutes. Allow the entire cycle to run so the resin is
rinsed clean.
4.
When the rinse cycle is complete, the control screen will move on to the brine fill (
bF
).
This phase will fill water back into the brine tank. You should gradually start to see the
water level rise to half a tank full. Let the entire brine fill finish.
5.
When the regeneration cycle is complete, open the outlet side of the bypass completely
allowing water to flow into your home. From this point, locate the nearest treated water
faucet. Remove the aerator screen and run the cold water until the water is completely
clear. Once done, shut off the faucet water and place the aerator screen back on the
faucet.
STEP 3.
Programming the System
IMPORTANT!
The settings are pre-programmed from the factory to work with the majority of
homes. We recommend programming the system from settings 1 - 4 and leave settings 5 - 8 at
system default unless the condition of water requires adjustment.
Enter Setting Menu by pushing both the ENTER button and UP button at the
same time. The screen will jump from the service screen with the faucet icon to
the first setting screen to set time.
Flashing
SEt - 1 tIME
11
:
30
1000 gAL
11
:
30
Summary of Contents for HARMONY Series
Page 2: ......
Page 33: ...30 AQUASURE HARMONY SERIES NOTES...
Page 34: ...31 www AQUASUREUSA com Tel 1 800 661 0680 NOTES...
Page 35: ...32 AQUASURE HARMONY SERIES...
Page 36: ...www AquasureUSA com 800 661 0680 support aquasureusa com...