background image

     IMPORTANT!

For optimum performance and
protection against hard water, please 
fully read this owner’s manual before 
proceeding with installation.

OWNER’S

MANUAL

(c) 2021 Aquasure USA - All Rights Reserved

Version 4.0 DEC 2020

HARMONY SERIES

WHOLE HOUSE WATER SOFTENER

Summary of Contents for HARMONY Series

Page 1: ...nce and protection against hard water please fully read this owner s manual before proceeding with installation OWNER S MANUAL c 2021 Aquasure USA All Rights Reserved Version 4 0 DEC 2020 HARMONY SERI...

Page 2: ......

Page 3: ...ing off the main water supply valve 7 STEP 2 Mounting the Control Valve 8 STEP 3 Connecting the Softener 9 STEP 4 Connecting the Brine Tank 10 STEP 5 Flushing and Testing the Plumbing Lines 12 SYSTEM...

Page 4: ...ease thoroughly read this manual The information listed in this manual covers the steps for a self serve installation In the event that you need support our Aquasure technicians are available to answe...

Page 5: ...______________________________________________________ City _____________________________________________________________________________ State ________________________________________________________...

Page 6: ...9 Grid Plate 10 Brine Tank 11 6 of 3 8 Brine Line 12 10 of 1 2 Drain Line 13 Power Adapter 14 Brine Well 15 Float Valve 16 Brine Drain Connection Required Tool List for System Installation Channel Loc...

Page 7: ...checklist Not for use with microbiologically unsafe water Pre filtration to remove contaminants and heavy sediment recommended to ensure optimum performance and product life Properly ground to confor...

Page 8: ...n areas with sharp protrusions The system works on standard 110v power plug only Do not use any other transformer except the one that is included with the system Transformer must be plugged into an in...

Page 9: ...Drain III Installation Diagram The following diagram displays how the water softener should be installed with a well or city water setup If you have city water your plumbing arrangement will vary but...

Page 10: ...r supply valve of the house and turn off completely by turning the shut off handle clockwise 2 Test to see if the water is completely shut off by turning on the closest faucet in the cold water positi...

Page 11: ...nk Thread the valve on the tank by turning it clockwise Be sure not to cross thread the valve on the tank The valve should thread easily in the tank If not it may be cross threaded DO NOT LUBRICATE as...

Page 12: ...g away from the valve is the outlet 3 Apply the plumber s tape onto the bypass inlet and outlet fittings 4 Connect the inlet and outlet of the softener using appropriate fittings 5 All piping should b...

Page 13: ...eeded and can potentially cause overfill in the brine tank and result in leaks STEP 4 Connecting the Brine Tank 3 Your brine tank system is 90 pre assembled To finish the setup unscrew and remove the...

Page 14: ...ional plumbing hose and place the hose onto the connection for a secure seal Typically the other end of the hose will feed off into a floor drain laundry style sink or dedicated drain connection Brine...

Page 15: ...fore proceeding and shut off the nearest faucet when water runs clear Service Position Bypass Position WARNING If the system is leaking at all turn the unit to the bypass position and shut off main wa...

Page 16: ...the valve Please be familiar with the buttons to operate the control valve 1000 gAL 11 30 To Cancel Regeneration During regeneration if there is a need to stop the process press the simultaneously to...

Page 17: ...the saltwater to bond with the resin After the BD the rapid rinse rr will start for a duration of 10 minutes Allow the entire cycle to run so the resin is rinsed clean 4 When the rinse cycle is compl...

Page 18: ...s the ENTER button to accept and continue Press UP or DOWN buttons to change minutes IMPORTANT The system will default to regenerate at 2 am in the morning based on the time entered in the setting Set...

Page 19: ...ELAYED Regenerate at 2 am on the night after the set gallon reaches zero Press the ENTER button to accept and continue IMPORTANT The system offers three mode types depending on your needs It is recomm...

Page 20: ...as selected User will not see this setting if t Timer mode was selected The system default is 1000 gallons with the option to change the unit measurement and the capacity of the water treated before t...

Page 21: ...rs Hours Override range Every 24 hours 24 48 72 960 Default 2 00 a m OFF Hours Override range Every 24 hours 24 48 72 960 4 Regeneration Time and Hours Override t Time Mode M Meter or tM Time Meter Mo...

Page 22: ...lso helps create space in between the resins to allow more contact surface for the next stage of regeneration The default setting is 15 minutes Flashing 1 2 3 Flashing Press the ENTER Button to accept...

Page 23: ...d continue to next digit Press Up or Down buttons to change Water Filling Time Minutes Range 0 999 8 Setting the Water Filling Time Recommend keeping at factory default setting Default setting is 012...

Page 24: ...pacity AS HS32D System 32 000 Grains chart above Feed Water Hardness 25 GPG must be tested on site by the end user or installer Number of People 3 1 055 Gallons would be inputted for Total Gallons dur...

Page 25: ...Total Gallons ONLINE GALLONS CALCULATION TOOL Use your phone to scan the QR code below or visit aquasureusa com calculationtool for our online gallons calculation tool If you need further assistance...

Page 26: ...generation Mode The display will show the current time and the remaining treated water alternatively When the remaining treated water counts down to zero the display changes to the countdown of time t...

Page 27: ...egeneration in TIMER Mode The display shows the Queued Regeneration in Meter Delay Mode The system will initiate a regeneration either the treated water remaining counts down to zero or the remaining...

Page 28: ...DUCT DIMENSIONS C B A Aquasure Water Softeners Capacity In Grains Tank Size A B C 24 000 8 x44 52 44 8 32 000 8 x44 52 44 8 40 000 9 x48 56 48 9 48 000 10 x54 62 54 10 64 000 12 x52 60 52 12 80 000 13...

Page 29: ...0 Regeneration Backwash Downflow Upflow Downflow Cycles 5 Adjustable Cycles All Time Available Up to 999 minutes per cycle Meter Accuracy Range Turbine Paddle 0 25 15 gpm 0 95 57 lpm 5 Capacity Range...

Page 30: ...56011 Brine House Barb 90 Elbow 22 1 A 13173 DLFC Button Retainer Assembly 23 1 DLFC Button 24 1 A 13245 BLFC Button Retainer 25 1 BLFC Button 26 1 A 12977 O ring 27 1 A 13244 BLFC Fitting 28 1 A 1276...

Page 31: ...28 AQUASURE HARMONY SERIES IN OUT 1 2 3 4 Item No Quantity Part No Description 1 1 A 19791 01 Meter Cable Turbine AQT 56SE 2 4 A 13305 O ring 3 2 A 13255 SE Adapter Clip 4 2...

Page 32: ...erated in accordance with specifications and not subject to freezing General Provisions Aquasure assumes no responsibility for incidental damage consequential damage or other damages including but not...

Page 33: ...30 AQUASURE HARMONY SERIES NOTES...

Page 34: ...31 www AQUASUREUSA com Tel 1 800 661 0680 NOTES...

Page 35: ...32 AQUASURE HARMONY SERIES...

Page 36: ...www AquasureUSA com 800 661 0680 support aquasureusa com...

Reviews: