STEP 4.
Attaching the Water Supply Pipe to the Pre-Filter
1. Wrap the 1” male threaded fittings that will be used to connect the
plumbing to the pre-filter with five (5) to six (6) wraps of Teflon tape.
2. Attach the 1” male threaded fitting from the incoming water supply
plumbing to the
IN
port and
OUT
port of the pre-filter system.
Note:
Use the 1” to 3/4” inch male adapter for 3/4” plumbing
STEP 5.
Installing the Pre-Filter Cartridge
1. Unwrapp the filter cartridge and place it inside the
housing. Make sure the filter is centered on the stand
pipe located inside the housing at the base.
2. Screw on the housing with the filter inside and
screw onto the corresponding head by turning it
counterclockwise using the supplied housing wrench.
Note:
Make sure the o-ring is inside the housing
and do not over tightening the housing.
STEP 3.
Mounting the Pre-Filter
1. Position the system on the wall at the desired mounting
location with minimum of six (6) inches of ground clearance
from the floor to the base of the system.
2. Using a pen or pencil and mark the mounting hole on the
back of the bracket onto the wall.
Note:
Please make sure the bracket mount is leveled using
a leveling tool to ensure evenly distributed stress on the
bracket. Make sure the mounting point is position on a stud
to properly secure the bracket.
3. Mount the system onto the wall using the provided Lag Bolts
and Washers.