background image

8

AQUASURE 

FORTITUDE PRO SERIES

STEP 4. 

Attaching the Water Supply Pipe to the Pre-Filter

1.  Wrap the 1” male threaded fittings that will be used to connect the 

plumbing to the pre-filter with five (5) to six (6) wraps of Teflon tape. 

2.  Attach the 1” male threaded fitting from the incoming water supply 

plumbing to the 

IN

 port and 

OUT

 port of the pre-filter system.  

Note:

 Use the 1” to 3/4” inch male adapter for 3/4” plumbing

STEP 5. 

Installing the Pre-Filter Cartridge

1.  Unwrapp the filter cartridge and place it inside the 

housing. Make sure the filter is centered on the stand 
pipe located inside the housing at the base.  
 

2.  Screw on the housing with the filter inside and 

screw onto the corresponding head by turning it 
counterclockwise using the supplied housing wrench.  

Note:

 Make sure the o-ring is inside the housing 

and do not over tightening the housing. 

STEP 3. 

Mounting the Pre-Filter

1.  Position the system on the wall at the desired mounting 

location with minimum of six (6) inches of ground clearance 
from the floor to the base of the system.

2.  Using a pen or pencil and mark the mounting hole on the 

back of the bracket onto the wall. 

Note:

 Please make sure the bracket mount is leveled using 

a leveling tool to ensure evenly distributed stress on the 
bracket. Make sure the mounting point is position on a stud 
to properly secure the bracket. 

3.  Mount the system onto the wall using the provided Lag Bolts 

and Washers.

Summary of Contents for FORTITUDE PRO Series

Page 1: ...FORTITUDE PRO SERIES WHOLE HOUSE WATER TREATMENT SYSTEM Version 4 0 022822 Aquasure USA All Rights Reserved...

Page 2: ......

Page 3: ...Supply Valve STEP 3 Mounting the Pre Filter STEP 4 Attaching the Water Supply to the Pre Filter STEP 5 Installing the Pre Filter Cartridge STEP 6 Attaching the Water Supply Pipe to the System STEP 7 M...

Page 4: ...fectiveness please thoroughly read this manual The information listed in this manual covers the steps for a self serve installation In the event that you need support our Aquasure technicians are avai...

Page 5: ...___________________________________________________________________________________ City _____________________________________________________________________________ State __________________________...

Page 6: ...ange or diagnosis INSPECTION PREPARATION x 8 x 8 x 3 x 3 x 5 x 5 10 Pleated pleated sedemint filter is shown here Pre filter size may vary depending on the system configuration Pleated Sediment Pre Fi...

Page 7: ...A vacuum breaker may be needed for well water installation 4 Pre install environment checklist Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfecti...

Page 8: ...e tanks are designed to work with a floating base This allows the tank to be leveled on any surface Some applications may not have level surface to place the tank The floating base allows the tank to...

Page 9: ...g codes which actually encouraged the grounding of electrical appliances through plumbing A grounded jumper wire bridging the equipment and reestablishing the contiguous conductive nature of the plumb...

Page 10: ...flow and determine if water is flowing from left to right or right to left 2 If needed reassemble the mounting bracket for the pleated sediment filter if the direction is opposite of where the mountin...

Page 11: ...e base 2 Screw on the housing with the filter inside and screw onto the corresponding head by turning it counterclockwise using the supplied housing wrench Note Make sure the o ring is inside the hous...

Page 12: ...l three openings Note Make sure the o ring is inside the housing and do not over tightening the housing 1 Apply a small amount of lubricant onto the o ring of the valve body Do not apply lubricant on...

Page 13: ...nd push the valve on the tank Thread the valve on the tank by turning clockwise Be sure not to cross thread the valve 5 Tighten the vale hand tight then snug it further by tapping it with the palm of...

Page 14: ...eplace the filter in the suggested replacement time 1 Find the nearest water faucet and remove the aerator or grid mesh on the faucet Turn on the faucet before turning on the main water line to allow...

Page 15: ...orm a Fast Rinse cycle More time may be needed if desired result is not achieved FAST RINSE Fast Rinse setting is used immediately after the Backwash cycle The Fast Rinse process forces the media to s...

Page 16: ...to the left to loosen 3 Discard the old filter and clean the inside of housing and cap with warm water Caution Do not use any chemical to wash the housing STEP 3 Install the New Filter 1 Unwrapped the...

Page 17: ...eceive your new filters That s it Cancel or change your delivery frequency at any time Save time and money when replacing your Aquasure Pleated Sediment Filter with our Subscribe and Save program Get...

Page 18: ...shall further be limited to repair or replacement with the styles models products colors etc of the Product that are available at the time of the repair or replacement and shall be limited to the repa...

Page 19: ...forming product or parts of the product or at the option of Aquasure return of the product and a refund of the purchase price Buyer assumes all risk whatsoever as to the result of the use of the produ...

Page 20: ...www AquasureUSA com 800 661 0680 support aquasureusa com...