To replace the modules K5 and K7:

Set the input tap on the connection node to the "Closed" position and open the fresh water tap to to relieve the pressure.

Press the stop button all the way down and while holding it, turn the filter module counter-clockwise and remove it.

Remove the heat shrinkable film from the new module.

Wash the module O-rings under running water.

Insert the module into the appropriate manifold until all the way in and, gently pushing it, turn the module clockwise till it clicks.

Set the input tap on the connection node to the "Open" position and make sure that the water purifier is sealed.

ATTENTION! Replacement and maintenance of the tank with replaceable backfilling should be done by the servicing unit.

Lifetime of the tank with replaceable backfilling depending on the hardness of the water

7. Replacement of modules. See Fig. 6

ATTENTION! These figures are relevant for a new tank with replaceable backfill.

8. Rules of storage and transportation

Shelf life of the water purifier before the start of operation is 3 years at a temperature of + 5 to + 35 ° C, in polyethylene packaging and
carton in closed rooms with natural ventilation with relative humidity not exceeding 80%. Do not tilt the water purifier, subject it to
mechanical impacts and other influences.
The water purifier can be transported by all types of covered vehicles.

Hardness, degrees

Amount of water, m3

1

1

20.9

2

2

10.5

3

3

7

4

4

5.2

5

5

4.2

6

6

3.5

7

7

3

8

8

2.6

9

9

2.3

10

10

2.1

Summary of Contents for EXTRA-SOFT

Page 1: ...Water purifier EXTRA SOFT Manual LLC Aquaboss Russia...

Page 2: ...ion 4 5 Installation 4 6 Starting 4 7 Replacement of modules 6 8 Rules of storage and transportation 6 4 Security 6 5 Manufacturer s warranty 8 Troubleshooting 9 Service maintenance of water purifier...

Page 3: ...hygienic requirements and requirements of TU 3697009 50056997 2010 1 Requirements for water supply The water purifier is designed for post treatment and water softening corresponding to SanPiN 2 1 4...

Page 4: ...it Connect the supply pipes and perform the washing procedure of the modules Connect the supply pipes following the diagrams below Connecting the JG pipes Pull the locking clip 2 out of the plastic bu...

Page 5: ...s service mode for air removal see fig 3 and close the input tap Gently remove the service plug remove the corner install the tube in place of the service plug and put the clip operating mode see Fig...

Page 6: ...t and maintenance of the tank with replaceable backfilling should be done by the servicing unit Lifetime of the tank with replaceable backfilling depending on the hardness of the water 7 Replacement o...

Page 7: ...ore than 2 weeks perform a full wash cycle according to the instructions in Section 6 Starting up in this manual ATTENTION Do not drink the purge water the water that was obtained as a result washing...

Page 8: ...ost with the dates of production and or sale fixed and there are no other ways to determine the service life of the product The manufacturer is discharged of liability in the following cases the consu...

Page 9: ...sure Install the boost pump on the whole apartment or separately on the water purifier Foreign object in one of the supply tubes Contact the after sales service Water from a tap of clean water flows s...

Page 10: ...Service maintenance of water purifier Date Work executer Type of work Note...

Page 11: ...tion July 19 2018 Valid from the registration date on 18 07 2023 including The Declaration of Conformity is issued by LLC Aquaboss 197183 Russia St Petersburg Sestroretskaya St 3 lit A p 1H 3 1 TU 369...

Page 12: ...rg st Pionerskaya 27 27 lit A Companies performing installation warranty and service maintenance Engineering centre of LLC Aquaboss Russia St Petersburg st Sestroretskaya 3 3 tel 812 430 55 06 Russia...

Reviews: