9. STORAGE AND TRANSPORTATION

10. SAFETY

Pay attention!

During installation:

•   

   

•   

Operating:

•   

   

 

 


•   

•   

 

   

   


   

-

The membrane cartridge is supplied in sealed packaging. Having opened the package, store the membrane 

cartridge for no longer than 3 days. Do not expose the membrane cartridge to high and low temperatures, direct 

sunlight. It is prohibited to turn the DWM over, hit it and expose to mechanical i

nfl

uences.

The DWM is transported by all kinds of covered vehicles.

Dispose in accordance with environmental, sanitary and other requirements established by national standards 

of environmental protection and sanitary-epidemiological well-being of the population.

It is not recommended to carry out the connection of the DWM to the water mains by yourself.
This work should be performed by a specialist authorized to conduct this type of work.
The manufacturer is not liable for the improper DWM connection to the water supply, as well as for the result 

of this work.
The user is responsible for the shortcomings of this work, as well as for damage to health or property of the 

user or other persons in the result of shortcomings of his work.
Do not replace the supplied connection assembly with a connection assembly of any other model.

The  DWM  is  designed  for  puri

cation  and  softening  corresponding  to  SanPin  2.1.4.1074-2001  Drinking 

water.
When installing the DWM out of central drinking water supply, it is recommended to analyse the raw water 

in order to to meet the requirements SanPin 2.1.4.1074-2001.
If  the  source  water  does  not  meet  the  requirements  of  SanPin  2.1.4.1074-2001,  service  life  of  the 

pre-

ltration cartridge and membrane cartridge shall be signi

cantly reduced.

If the source water does not comply with the requirements of SanPin 2.1.4.1074-2001, it is recommended to 

install  an  additional  water  treatment  system 

(

iron 

lter,  softener,  dechlorinators,  disinfection  systems, 

mech

anical cleaning, etc.)

.

After DWM installation, check the puri

fied 

water.

In the future, to ensure the proper operation of the DWM, the puri

fied

 water should be checked about once a 

year.
In case of unsatisfactory results of the analysis, do not drink the water, but contact your service provider.
Although  DWM  capable  of  retaining  bacteria  and  viruses  that  may  be  present  in  the  source  water,  it  is 

recommended to use the system with the water microbiologically safe.
Do not use the water of unknown quality, without additional disinfection.
Use the DWM only for treating water from a cold water supply system.
If  the  ambient  temperature  during  operation  of  the  DWM  reaches  38°C  and  higher,  the  DWM  must  be 

disconnected from the cold water line until the temperature drops.
If you know that the DWM will not be used within the day or longer 

(f

or example, when leaving for summer 

cottag

e)

, it must be disconnected from the cold water mains

 (

connectio

n assembly shall be turned off)

.

If you do not use the DWM more than for two weeks, collect and 

ush the water from the collection bowl and 

allow it t

o be fi

lled again.

Avoid freezing of the DWM, as well as direct sunlight, contact with hot o

bj

ects, including hot water piping 

and heating.
Avoid bumps and falls.
Puri

fied 

water is not su

bje

ct to long-term storage.

We recommend using fres

h fi

ltered water. 

Summary of Contents for DWM-31

Page 1: ...AQUAPHOR RO 31 DWM 31 DRINKING WATER MACHINE WATER FILTERS Instruction manual LLC Aquaphor Russia 41 31...

Page 2: ...ter cartridge KP5 5 2 Replacement lter cartridge K2 5 3 Membrane cartridge 6 Water connections blue supply 1 2 m red drainage 1 3 meters with built in ow restrictor 7 Tube tip 8 Connection assembly 9...

Page 3: ...r cartridges and automation valves and has holes for wall mounting Water treatment unit 1 provides pre cleaning and preparation of water for the membrane separation stage The unit comprises a replacem...

Page 4: ...ay so that they cannot be damaged or pulled out of the sockets by foreign bodies The DWM must be distanced or isolated from heat sources such as dishwashers and washing machines cookers boilers hot wa...

Page 5: ...mmended to install the clamp on the drainage line in front of the siphon the drain clamp ts to most drainage lines with diameters of about 40 mm Remove the protective lm from the gasket 1 Glue the gas...

Page 6: ...it stops at a depth of about 15 mm and install the clip into the place Check the holding strength of the tube xing the tube should not be removable by a force of 8 10 kgf applied To disconnect the tu...

Page 7: ...ng the tip in one hand put the shutoff device into the sink and leave the water draining out from the water puri er for 60 minutes Disconnect the tip from the shutoff device by clicking on the button...

Page 8: ...r Fig 11 and 11b show the correct and incorrect placement of the tube and the collection bowl during lling with water At the wrong positioning of the tube the tip s automatic shut off system may be de...

Page 9: ...unscrew the nut counterclockwise holding it in this position it is unnecessary to keep the lock pressed after turning the nut at the angle of more than 5 Fig 15a Pull the cover and remove the used lte...

Page 10: ...water does not meet the requirements of SanPin 2 1 4 1074 2001 service life of the pre ltration cartridge and membrane cartridge shall be signi cantly reduced If the source water does not comply with...

Page 11: ...the modules is speci ed for usage of the water that corresponds to SanPin requirements If the water supplied into the puri er water does not meet the SanPin requirements and has a high content of sol...

Page 12: ......

Page 13: ...e Low inlet pressure Installation of boost pump for the whole apartment or separately for the lter A foreign object in one of the lead tubes Contact the customer service Collection bowl is full but th...

Page 14: ......

Page 15: ...te Installation of Aquaphor RO 31 DWM 31 carried out Name of the organization carried out the installation Surname Name of the installer Installer s signature Customer s signature Firms involved in in...

Page 16: ...AQUAPHOR Westaqua Distribution O P rnu mnt 139D 2 11317 Tallinn Estonia www aquaphor com AQUAPHOR...

Reviews: