AQUAPHOR DWM-31 Instruction Manual Download Page 2

Click & Turn (Easy to use). 

RF Patent No. 2333779.

Easy replacement of cartridges. Clean and safe service. 

STC (Safe To Consume) (Absolute Safety)

2

DWM 

is a new category of professional home appliances that allows obtaining physiologically relevant

drinking water of PREMIUM CLASS regardless of quality of the source water.

Aquaphor DWM 

is a combination of the world's best achievements in water treatment and Aquaphor’s

technologies.

1. LIST OF PARTS

No.    Name 

   

 

 

 

 

 

 

 Qty

1. Collection bowl with cover and float 

2. Shutoff  

3. Mineralizer 

4. Manifold unit assembly 

5. Replacement cartridges

5.1 Replacement filter cartridge K5 (or collapsible replacement filter cartridge KP5)

5.2 Replacement filter cartridge K2 

5.3 Membrane cartridge 

6. Water connections

- blue - supply (1.2 m) 

- red - drainage (1.3 meters) with built-in flow restrictor

7. Tube tip 

8. Connection assembly 

9. Stand with clip and stopper 

10. Drain clamp 

11. Rinsing cap 

12. Fittings  

13. Instruction manual 

   

 

 

 

1 pc.

1 pc.

1 pc.

1 pc.

1 pc.

1 pc.

1 pc.

1 pc.

   

1 pc.

1 pc.

1 pc.

1 set

1 set

1 pc.

1 set

1 pc.

Аqualen™

Patent No. 20704036 (RF). 

Unique ion-exchange fiber. Effectively and permanently removes 

heavy metals.

 

CFB (CarbFiber Block) 

RF Patent No. 2282494.

Carbonblock with Aqualen™ completely removes chlorine, organic substances, and

carcinogens. Absorbs free radicals.

DWAY (DOUBLE WAY) 

 The unique technology of water conditioning and optimizing of the

Materials are certified for contact with drinking water and food

.

Figure 1

1

3

4

2

5

pH balance and trace elements.

Summary of Contents for DWM-31

Page 1: ...AQUAPHOR RO 31 DWM 31 DRINKING WATER MACHINE WATER FILTERS Instruction manual LLC Aquaphor Russia 41 31...

Page 2: ...ter cartridge KP5 5 2 Replacement lter cartridge K2 5 3 Membrane cartridge 6 Water connections blue supply 1 2 m red drainage 1 3 meters with built in ow restrictor 7 Tube tip 8 Connection assembly 9...

Page 3: ...r cartridges and automation valves and has holes for wall mounting Water treatment unit 1 provides pre cleaning and preparation of water for the membrane separation stage The unit comprises a replacem...

Page 4: ...ay so that they cannot be damaged or pulled out of the sockets by foreign bodies The DWM must be distanced or isolated from heat sources such as dishwashers and washing machines cookers boilers hot wa...

Page 5: ...mmended to install the clamp on the drainage line in front of the siphon the drain clamp ts to most drainage lines with diameters of about 40 mm Remove the protective lm from the gasket 1 Glue the gas...

Page 6: ...it stops at a depth of about 15 mm and install the clip into the place Check the holding strength of the tube xing the tube should not be removable by a force of 8 10 kgf applied To disconnect the tu...

Page 7: ...ng the tip in one hand put the shutoff device into the sink and leave the water draining out from the water puri er for 60 minutes Disconnect the tip from the shutoff device by clicking on the button...

Page 8: ...r Fig 11 and 11b show the correct and incorrect placement of the tube and the collection bowl during lling with water At the wrong positioning of the tube the tip s automatic shut off system may be de...

Page 9: ...unscrew the nut counterclockwise holding it in this position it is unnecessary to keep the lock pressed after turning the nut at the angle of more than 5 Fig 15a Pull the cover and remove the used lte...

Page 10: ...water does not meet the requirements of SanPin 2 1 4 1074 2001 service life of the pre ltration cartridge and membrane cartridge shall be signi cantly reduced If the source water does not comply with...

Page 11: ...the modules is speci ed for usage of the water that corresponds to SanPin requirements If the water supplied into the puri er water does not meet the SanPin requirements and has a high content of sol...

Page 12: ......

Page 13: ...e Low inlet pressure Installation of boost pump for the whole apartment or separately for the lter A foreign object in one of the lead tubes Contact the customer service Collection bowl is full but th...

Page 14: ......

Page 15: ...te Installation of Aquaphor RO 31 DWM 31 carried out Name of the organization carried out the installation Surname Name of the installer Installer s signature Customer s signature Firms involved in in...

Page 16: ...AQUAPHOR Westaqua Distribution O P rnu mnt 139D 2 11317 Tallinn Estonia www aquaphor com AQUAPHOR...

Reviews: