VCS – Viscosity Controller
21
7.4
Disposal
At the end of its life cycle, this product should be disposed of according to local regulations
regarding waste recycling or disposal.
Batteries and rechargeable batteries shall be recycled separately.
The separate collection and recycling of used products will help to conserve natural resources,
and ensures that they are disposed of in a way that does not cause damage to the environment
and nature.
8
Technical data
8.1
Hardware characteristics
Body
Display
Two lines dot matrix
Keypad
3 Tactile membrane keys
Size
96x96x150
Weight
0,5kg approx.
Panel Cut-out
B+0,8 / H+0,8
Protection Class
IP54
(IP20 Terminals)
Environmental
Operating temperature Range
0-60°C
Operating humidity range
<75%RH (non-condensating)
Climate Category KWF to EN60529
Storage temperature range
-20 – 70°C
Vibration
Conforms to EN60068-2-6
Electrical
Supply range
100 – 240 V AC
50-60Hz
Alternative 24 V AC/DC
Power consumption
14W max
Relays Contact
Potential free, switching power 250V 2A
Summary of Contents for Viscosity VC312