12
VCS – Viscosity Controller
LNG
Language selection of the menu text (Deutsch, English, User def, Off)
English
CONF
Selection of the configured controller function (if existent)
return
to operating mode: Briefly press the button
or:
continue
to the following settings: press the -button and hold
it > 5 sec:
Note: when continuing after changing a function, the display first
flashes for a few seconds, only then does the desired switching over
or back take place
SPEF
Configuration external/second setpoint “BIN” (activation by binary
input)
/ “MENU” (activation from the setpoint level) / “SP2” / “AUS”=OFF
MENU
AIN*
Input type for input no.*: "RTD / 0 to 20 / 4 to 20(mA) / 0 to10 /
2 to 10 (V) / AUS=OFF" (note different terminals for I/U!)**
4 to 20
mA
IST*
Correction value for changing the controller display (+/-)
SP 2/E
Type of effect of second / external setpoint: "Add/ Sub/ AbS"
(adding / subtracting / absolute value)
AbS
*YM
Setting time of the controlled drive “6 to 600” (sec)
60 sec
*CY' '
Switching frequency in two-point controllers: "2 to 120" (sec.)
20 sec
*OUT
Setting output signal "0 to 20 / 4 to 20" (mA) /0 to 10 / 2 to 10 (V)“
4 to 20
mA
*OUT
Setting output characteristic: direct / inverse "di / in"
(with 2 outputs: "in in / in di / di in / di di")
in
in in
0
*td
For 2 outputs: dead zone between outputs 1 and 2 “0…10%”
0.0
*
AP
Output signal working point (-100 to +100)
50
FG A/E
Automatic adjustment of remote transmitter input (see extra sheet 99ar)
Sou*
Assignment of inform. output signal(s)* (act. value/setp., setting var..) Ist1
Sou*
Type of information output signal(s)* “0 to 20/4 .to 20(mA)/
0 to 10/2 to 10(V)”
(* Sout= Signal 1; Sou2 = Signal 2)
*Y_S
Behaviour of the setting output in the event of measurement line
error:
Relay position: "rel1 / rel2 / OFF"
Continuous output: "0...100" (%)
rel2(70.)
rel1(20.)
bin.Ein
g
Sub-menu for binary input configurations
Polling: press the button and hold it > 5 sec
BIN*
Direction of control action binary input* direct / inverse (di/in)
di
BIN*
Assignment of collective relay: Stat=none, SREL= collective relay
Stat
BIN*
Switch-on delay (0…300 sec)
0
REL*
Function mode of additional contact (relay no.)
LCA / LCE
REL*
Measuring input / control loop assigned to additional contact
IST 1
REL*
Add. contact – relay pos. in event of meas. line error "SiE/SiA"(on/off)
Si A
DSPL
Display representation: NORM (grey / black), INV (black / white)
NORM
Adr
if equipped with interface: bus address (number)
5
BAUD
if equipped with interface: baudrate (9600/ 19200/ 38400)
38400
return to operating mode: briefly press the button again
*
= ID number in case of several inputs / outputs or control loops.
**
= Rtd input of ain2 is additionally usable if equipped with ext. setpoint and activation using SP-F
Summary of Contents for Viscosity VC312
Page 23: ...VCS Viscosity Controller 23 ...
Page 24: ...24 VCS Viscosity Controller ...
Page 25: ...VCS Viscosity Controller 25 ...
Page 26: ...26 VCS Viscosity Controller ...
Page 27: ...VCS Viscosity Controller 27 8 3 2 VC622 322 622 722 controller connection ...
Page 28: ...28 VCS Viscosity Controller ...
Page 29: ...VCS Viscosity Controller 29 ...
Page 30: ...30 VCS Viscosity Controller ...
Page 31: ...VCS Viscosity Controller 31 ...