28
Before working on the hydraulics:
put the system or section out of operation
close the stop valves
release the pressure
put a suitable tray underneath the connection to be worked on
be prepared for spillage, have absorbent at hand
Cleaning of flow meter:
do not use any aggressive solvents
rinse hydraulic part of flow meter thoroughly
Aquametro Oil & Marine recommends to use the following cleaning solvents:
Gasoline used for cleaning purposes
Cleaner’s naphtha
Petroleum ether
Dirt filter
(not safety filter of flow meter)
:
Dirt filters must be cleaned periodically, initially at short intervals to keep fuel system free of
dirt and debris.
To restart the system:
slowly open the stop valves, avoiding pressure
surges (“water hammer”)
vent the pipe well
check tightness
Summary of Contents for CONTOIL VZF II
Page 9: ...9...