II INSTALLATION
- Protect the electrical circuit to the pump by a 30mA RCD, ensuring the proper grounding of
your installation. if in doubt consult a qualified professional.
- Position the pump horizontally at 3.50 m over the basin, below the level of water in a dry, well
ventilated, protected from rain. Leave a space of 30 cm behind the fan cover.- Ensure the accessibi-
lity of the strainer basket for regular cleaning.
- Set the pump on a solid base (concrete base filter, plank) using 2 screws adapted (not included).
- Set up the connections (not supplied) 1’’1 / 2 32-38 mm (Ref 200237 EAN13 : 3359192002376),
using PTFE tape.
- Install the suction and discharge of the pool by limiting the lengths and bends and avoiding traps.
It should not produce mechanical stress on the pump. For more comfort we suggest you install the
valves 1 / 4 turn (Ref : 200406 EAN13 : 335 919 200 4066) on the suction and discharge.
I GENERAL
This manual provides information about the installation, the use and maintenance
of your pump.
This pump is designed to ensure the flow of clean water and disinfected in a private swimming pool
filtration circuit. Any other application will invalidate any warranty and / or appeal with the supplier.
The water temperature should not exceed 35 ° C.
III INSTALLATION OF THE PIPE
- Check that the fan cover is well positioned and does not touch the propeller.
- Rotate the motor shaft by the fan screws with a screwdriver (the first start and after the rainy
season).
- Open the valves of the hydraulic system (if present) to fill to complete the pre-filter the water
pump. If necessary, remove the lid of the pre-filter and fill with water. Close it by checking the
correct position of the joint.
- Plug the pump into the mains. The pump begins in less than a minute.
- Damage resulting from dry running the pump are not guaranteed.
IV SERVICING
- Check that the fan cover is well positioned and does not touch the propeller.
- Rotate the motor shaft by the fan screws with a screwdriver (the first start and after the rainy
season).
- Open the valves of the hydraulic system (if present) to fill to complete the pre-filter the water
pump. If necessary, remove the lid of the pre-filter and fill with water. Close it by checking the
correct position of the joint.
- Plug the pump into the mains. The pump begins in less than a minute.
- Damage resulting from dry running the pump are not guaranteed.
A
ctions
d
Aily
Check the clogging of the prefilter
Daily
Clean the prefilter
If dirty
Check the cover gasket
Same cleaning prefilter
Drain and put in dry
A wintering pool
Replace the water level
If less than 2 / 3 of the height of the skimmer after
the bathing. (heat waves, prolonged absence, etc.)
V MAINTENANCE
C
auses
s
olutions
x
x
x
air entry
Check the tightness of connections, hose
and seal lid
x
x
Body of the pump without water
Fill the water pump housing
x
Hydraulic blocked
Dirty turbine
Clean the skimmer basket, pump prefilter,
then do a wash against the sand filter.
Requires the dismantling
x
Improper attachment of the pump
Secure properly ground pump
x
Foreign body in the prefilter.
Foreign body in the prefilter.
x
No voltage
Reset circuit protection.
x
Axis blocked
See 3.mise on (cover / Driver)
n
o
boo
t
l
o
w
flo
w
ra
te
u
nusu
al
noise
P
um
P
does
no
t
st
ar
t
In other cases, consult your dealer
6
5
HYDRAULIC CURVES
0.0
1.0
2.0
3.0
4.0
5.0
6.0
7.0
8.0
9.0
10.0
11.0
12.0
13.0
14.0
15.0
16.0
17.0
18.0
19.0
20.0
100517
100518
106454
106455
106456
Disconnect the pump before any intervention