HiQu Digital Concealed
installation instructions
Page 8
Place the Digital processor on a solid
mounting surface, and place the fixing feet
into suitable positions. Mark then drill and
prepare suitable fixings before securing the
processor to the mounting surface using the
screws provided.
4
Flush out the hot and cold supply pipes.
5
The maximum hot water inlet temperature must be no more than 65˚C
!
Choose the position for your Digital processor as close to the shower control
as possible.
The processor may be sited in the roof space above the proposed shower
site, in the airing cupboard or behind a screwed bath panel if more
convenient. If siting in the roof space, ensure that freezing cannot occur and
that no insulation material is placed under or over the processor.
Please refer to the system layout diagrams.
3
!
THE PROCESSOR MUST BE SITED IN A POSITION THAT IS SAFELY ACCESSIBLE
FOR SERVICING AND COMMISSIONING PURPOSES. WHEN FITTED IN THE LOFT
SPACE, THE ROUTE TO AND THE AREA AROUND THE PROCESSOR MUST BE
BOARDED TO ENSURE A SAFE WORKING ENVIRONMENT.
The optimum position for the Digital processor is in the roof space above the
shower site to take full advantage of the ease and speed of installation -
please refer to the note above.
The distance between the Digital processor and shower control must be
within range of the 10m data cable supplied.