HiQu Digital Concealed
installation instructions
Page 11
Connect the 15mm copper pipe to the mixed water outlet on the
Digital processor. Using pipe clips as appropriate, ensure that all
pipe work is perpendicular to the processor, i.e. not putting any
strain on the fittings.
14
Connect the processor power lead to
a double pole 3 amp fuse switched
spur incorporated in the fixed wiring
circuit, in accordance with current
wiring rules. Ensure that this is
located in an accessible, dry location
and not in the bathroom.
15
THIS APPLIANCE MUST BE EARTHED
We recommend protecting surface mounted cables in suitable
approved conduit to avoid the risk of damage from vermin.
The data cable and power lead should also be clipped in place with
‘P’ clips or similar to avoid accidents.
!
TO ENSURE OPTIMUM PERFORMANCE USE THE MINIMUM AMOUNT
OF ELBOWS.
TO MAXIMISE FLOW RATES WE RECOMMEND USING COPPER PIPE
WITH THE MINIMUM AMOUNT OF ELBOWS.
BEFORE ANY ELECTRICAL ADJUSTMENT IS ATTEMPTED, THE
ELECTRICITY SUPPLY MUST BE TURNED OFF AT THE MAINS SWITCH.
ELECTRICAL INSTALLATION MAY ONLY BE CARRIED OUT BY
A QUALIFIED PERSON.
!
!