HiQu Digital Concealed
installation instructions
Page 13
The Digital processors are supplied factory set
with the flow rate at either ‘NORMAL HP’ or
‘NORMAL GRAVITY’ mode depending on
which shower system has been ordered.
STANDARD PROCESSORS ON BALANCED HP
SYSTEMS:
Standard processors fitted to balanced high
pressure systems may be set to ‘NORMAL HP’
or for water economy ‘ECO’ modes.
N.B. As ‘ECO’ flow can be achieved by the HiQu Digital controller,
we recommend the processor is set to ‘NORMAL HP’ mode.
STANDARD PROCESSORS ON COMBINATION BOILER SYSTEMS:
For Standard Digital processors installed on combi boiler systems, for optimum
performance we recommend setting the flow rate to the ‘COMBI’ mode.
18
N.B. The ‘ECO’ flow rate mode should not be selected for shower systems
fitted to combination boilers.
PUMPED PROCESSORS:
Pumped processors fitted to gravity systems may be set to ‘NORMAL GRAVITY’
or for water economy ‘ECO’ flow rate modes.
N.B. As ‘ECO’ flow can be achieved by the HiQu Digital controller,
we recommend the processor is set to ‘NORMAL GRAVITY’ mode.
WHEN MAKING ANY ADJUSTMENT TO THE PROCESSOR SETTINGS THE
POWER MUST BE ISOLATED.
!
Re-instate the electricity supply to the processor and press the ‘start/stop’
button on the controller to turn the shower on.
19