![Aqualisa Axis Digital 8115 Installation Instructions Manual Download Page 15](http://html.mh-extra.com/html/aqualisa/axis-digital-8115/axis-digital-8115_installation-instructions-manual_2960085015.webp)
Axis Digital concealed
installation instuctions
page 15
Connect the pipe work from the valve to the pipe work for
the fixed head. Check that the shower head is still in the
correct position before fully tightening the nut on the ceiling
mounting bracket using a 32mm spanner.
11
Check the installation for leaks then fit the badge to the front
of the spray plate.
12
Wall mounted
The wall mounted fixed head is supplied with masonry
fixings intended for use with a wall of solid construction only.
If the unit is to be installed on a wall of different construction
then please use alternative fixings as required.
The maximum panel thickness for installation of the fixed
shower head is 35mm, this includes a maximum tile thickness
of 15mm.
!
Run a 15mm outlet pipe from the shower valve/processor to
the preferred position for the fixed head arm, the pipe must
terminate with a suitable 1/2” BSP female fitting.
1
If the spigot cannot to be secured to the wall then the pipe
must be secured using a clip or another form of fixing.
!
2
If the spigot is to be secured before tiling then the depth of
the tiles must be taken into consideration.
!
Secure the spigot into the
1/2” female fitting allowing
it to project to a length of
31-46mm measured from
the finished surface using
the washer and back nut as
required. A 12mm Allen key
can be inserted into the
front of the spigot to
facilitate tightening.