![Aqualisa Aquastream Thermo Installation Instructions Manual Download Page 7](http://html1.mh-extra.com/html/aqualisa/aquastream-thermo/aquastream-thermo_installation-instructions-manual_2960134007.webp)
Aquastream Thermo thermostatic integral power shower
installation instuctions
page 7
Set the temperature control to full cold
(9 o’clock). Insert a small flat headed
screwdriver into the screwdriver slot taking
care not to damage the surrounding plated
surfaces and carefully remove the
Aquastream Thermo control knob from the
unit by pulling it away from the product.
3
Set the control lever to mid-blend
(12 o’clock) position prior to removing the
three fixing screws and withdrawing the
lever. Remove the fixing screw from the top
of the Aquastream Thermo casing and pull
the front cover away from the unit.
4
The Aquastream Thermo has been designed to accept rear entry concealed
pipe work or exposed top or bottom entry pipe work.
!
Rear entry installation
The 15mm supply pipes must emerge at 90º
angles from the finished wall surface spaced
at 65mm centres. Ensuring correct alignment
of the gripper ring assembly, slide over the
projecting pipes flush to the wall surface.
Trim the supply pipes to their finished length
(18-22mm) using a rotary type cutter.
5
Briefly run the hot and cold supplies to flush out any debris that may be
present in the system.
6
Remove the bung from the rear inlets of the
Aquastream Thermo unit using a suitable
long nosed tool.
7
Lubricate the supply pipe ends using a silicone based lubricant and carefully
slide the Aquastream Thermo unit onto the pipes whilst feeding the low
voltage cable through the cable entry point. Secure the unit to the wall using
the screws provided.
Proceed to step 17.