Step-by-step instructions
In addition to the guide below it is essential that the written instructions
overleaf are read and understood and that you have all the necessary
components (shown overleaf) before commencing installation. Failure to
install the product in accordance with these instructions may adversely affect
the warranty terms and conditions. All showers requiring an electrical
connection must be installed by a qualified person following the latest
revision of BS 7671 (Wiring Regulations) and certified to current building
regulations.
!
The Aquastream Thermo is supplied with universal fixings.
!
Using the template provided, mark out the
fixing points and entry point for the low
voltage cable and rear entry pipe work as
necessary. Remove the template and
prepare suitable wall fixings and entry
points as required.
1
Site the transformer within 4 metres cable distance from the Aquastream
Thermo unit. Ensure that there is free air movement around the transformer
housing. Do not fit close to heating or hot water pipes as the transformer has
a maximum operating temperature of 40ºC. If the transformer is to be sited
in the bathroom area, it must be sited away from the bather behind a screw
panel. Allow 150mm working end of low voltage cable to project from the
wall. Suitable electrical conduit should be used to protect exposed or
concealed cables.
2
DO NOT MAKE ANY ELECTRICAL CONNECTIONS AT THIS POINT.
!
Typical gravity system installation
Supply
Vent and draw-off
pipe to hot water
Underside of cistern
Highest point
must be below
underside of
cistern
Hot water
cylinder
Connect
‘A’ or ‘B’
Cold feed
to cylinder
B
A