Important information

Introduction

The Aquastream Thermo power shower system is a surface mounted thermostatic shower unit with integral pump suitable for

top, bottom or rear entry pipe work. The thermostatic shower provides close temperature stability and fail safe protection when

installed on gravity fed systems.

If you have any questions at any stage during installation then please contact the Aqualisa customer helpline on 01959

560010 for advice.

The Aquastream Thermo shower system is designed to operate up to a maximum

static pressure of 0.1 MPa (1 bar)

(14.5 psi).

UNDER NO CIRCUMSTANCES SHOULD AN AQUASTREAM BE CONNECTED DIRECTLY TO THE WATER MAINS OR IN-LINE

WITH ANOTHER BOOSTER PUMP.

Safety information

This product must be installed by a qualified person in accordance with all relevant current Electrical and Water Supply

Regulations.

Electrical supply and bonding of the bathroom must comply with current IEE regulations with your attention particularly drawn

to the requirements concerning protective earth bonding.

The unit must not be installed in situations where the ambient temperature is likely to fall below 5ºC or rise above 40ºC.

Cables which are chased into the wall must be protected by the use of conduit or sheathing. Surface mounted cables must also

be protected by a suitable approved conduit.

ALL SHOWERS REQUIRING AN ELECTRICAL CONNECTION MUST BE INSTALLED BY A QUALIFIED PERSON FOLLOWING THE

LATEST REVISION OF BS 7671 (WIRING REGULATIONS) AND CERTIFIED TO CURRENT BUILDING REGULATIONS.

The Aquastream Thermo is suitable for household use only.

This product is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities or lack

of experience and knowledge, unless they have been given initial supervision or instruction concerning the use of the product

by a person responsible for their safety.

Children should be supervised to ensure they do not play with the product.

Flushing

Some modern fluxes can be extremely corrosive and, if left in contact, will attack the working parts of this unit. All soldering

must be completed and the pipe work thoroughly flushed out in accordance with current Water Supply Regulations prior

to connection of the product.

Connections

The Aquastream Thermo incorporates ’push fit’ type connections suitable for use with 15mm British Standard copper tube (it

is imperative that chrome plating is abraded where contact is made with the grip teeth). Tube should be cut using a rotary type

cutter and lubricated using a silicone based lubricant or petroleum jelly (Vaseline or similar) prior to insertion into the fitting.

Supply lines should be flushed clear of any debris prior to installation of the unit. The Aquastream Thermo is supplied for

connection to conventional supplies with HOT on the LEFT and COLD on the RIGHT when viewed from the front.

THE AQUASTREAM THERMO IS NOT SUITABLE FOR REVERSED CONNECTIONS.

THE AQUASTREAM THERMO IS NOT SUITABLE FOR STAINLESS STEEL TUBE.

If plastic pipe is to be used, the tube insert must not increase the tube diameter or extend the cut off length by more than

2mm.

Summary of Contents for Aquastream Thermo

Page 1: ...ctronic Equipment Producer Responsibility Regulation 2004 This product is outside the scope of the European Waste Electrical and Electronic Equipment Directive as interpreted within the UK In the UK t...

Page 2: ...Aquastream Thermo thermostatic integral power shower installation instuctions page 2 Aquastream Aquastream Thermostatic integral power shower...

Page 3: ...Aquastream Thermo thermostatic integral power shower installation instuctions page 3 Components...

Page 4: ...N FOLLOWING THE LATEST REVISION OF BS 7671 WIRING REGULATIONS AND CERTIFIED TO CURRENT BUILDING REGULATIONS The Aquastream Thermo is suitable for household use only This product is not intended for us...

Page 5: ...side of the cistern The casing must not be sited where it is subjected to continuous spray from the shower head Stored water capacities The minimum capacity of the cold storage cistern should not be l...

Page 6: ...y point for the low voltage cable and rear entry pipe work as necessary Remove the template and prepare suitable wall fixings and entry points as required 1 Site the transformer within 4 metres cable...

Page 7: ...entry concealed pipe work or exposed top or bottom entry pipe work Rear entry installation The 15mm supply pipes must emerge at 90 angles from the finished wall surface spaced at 65mm centres Ensurin...

Page 8: ...lower fixing screw and tighten the upper fixing screws 10 The pipe insertion depth measured from the point of entry into the top fitting is 160mm at 65mm centres Where plate copper tube is to be used...

Page 9: ...ed with a flat face which must be aligned before the knob is fitted Temporarily fit the on off control knob and rotate fully clockwise to the off position Turn the supplies on to check for leaks upstr...

Page 10: ...sformer assembly THE POWER SUPPLY TO THE AQUASTREAM THERMO MUST BE ISOLATED BEFORE REINSTATING THE DOMESTIC ELECTRICAL SUPPLY ALL COPPER PIPE WORK MUST BE CROSS BONDED AND CONNECTED TO A RELIABLE EART...

Page 11: ...itting into position into the top rail end body and secure the rail assembly to wall using the screws provided ensuring the rail and rail end bodies remain firmly engaged 27 Place the rail end covers...

Page 12: ...e lever screws into the top threaded hole in the temperature adaptor ring about 4 turns should be sufficient 4 To set the maximum desired temperature insert a limit pin into the mid position hole in t...

Page 13: ...aximum operating periods for this shower are 15mins on 45mins off Trouble shooting guide Check the fuse in the spur box or plug Check transformer cut out Symptom No power supply to the pump Pump fails...